Positioning On Site - Countertop - COMBITHERM CTP10-20E Installation Manual

Hide thumbs Also See for CTP10-20E:
Table of Contents

Advertisement

S I T E I N S T A L L AT I O N
4" (102mm) for plumbing
4-5/16" (109mm) with optional plumbing kit
NOTICE: • A minimum distance of 18" (457mm) is strongly recommended for service access. If adequate
service clearance is not provided, it will be necessary to disconnect the gas, water, and
drain to move the oven with a fork lift for service access. Service charges in connection with
inadequate service access is not covered under warranty.
• do not install a stacked combination directly over a drain. Steam rising up out of the drain
will adversely affect operation, hamper cooling air circulation, and may damage electrical
and electronic components. Failure to do so will void the warranty. A single oven installed
on a stand with solid surface bottom shelf can be positioned over a drain since the solid
surface will block the rising steam.
pOSITIONINg ON SITE – COuNTERTOp
Place the oven on a stable, non-combustible level horizontal
surface. Use the adjustable feet to overcome an uneven floor
and ensure that the unit is level.
It is strongly recommended that table top models be
mounted on a factory supplied stand or a stand that is stable,
open, and level. The adjustable oven legs should be extended
beyond the depth of the positioning ring to allow for leveling
after the oven has been placed on
the stand.
Each of the legs on the stand and
the oven can be adjusted
2" (51mm) up or down.
Level the oven from front-to-back
and side-to-side by means of the
adjustable legs. Components within
the oven condenser tank are sensitive to pitch and can be
can can be damaged. The tolerance to level is +/- .125".
If this tolerance range
is not achievable, the
floor must be repaired
to obtain level.
MN-35947
Rev 12
11/16
Combitherm® CT PROformance™ and CT Classic Series Installation Manual
mINImum CLEARANCE REQuIREmENTS
left side
0" (0mm) minimum
18" (457mm) recommended service access
right side
0" (0mm)
2" (51mm)
2" (51mm)
back
4" (102mm) for plumbing
4-5/16" (109mm) for optional plumbing kit
top
20" (508mm) for air movement
bottom
5-1/8" (457mm)
for legs and unobstructed air intake
Adjustable
Leg
Positioning
Ring
Positioning
Rings
Installation
-
from non
combustible surfaces
from combustible surfaces
for door swing
Adjustable
Leg
39

Advertisement

Table of Contents
loading

Related Products for COMBITHERM CTP10-20E

Table of Contents