Ctp7-20G Spec Sheet - COMBITHERM CTP10-20E Installation Manual

Hide thumbs Also See for CTP10-20E:
Table of Contents

Advertisement

43-3/4" (1111mm)
34-1/4" (870mm)
WATER REQUIREMENTS
TWO (2) COLD WATER INLETS - DRINKING QUALITY
ONE (1) TREATED WATER INLET:
ONE (1) UNTREATED WATER INLET: 3/4" NPT*
LINE PRESSURE: 30 psi minimum dynamic and 90 psi maximum static (200 to 600 kPa)
WATER DRAIN: 1-1/2" (40mm)
CONNECTION WITH A
.
MATERIALS MUST WITHSTAND TEMPERATURES UP TO
VENT
CLEARANCE REQUIREMENTS
LEFT: 0" (0mm)
0" (0mm)
RIGHT:
NON-COMBUSTIBLE SURFACES
TOP: 20" (508mm)
FOR AIR MOVEMENT
4" (102mm)
BACK:
4-5/16" (109mm)
OPTIONAL PLUMBING KIT
INSTALLATION REQUIREMENTS
• Oven must be installed level.
• Water supply shut-off valve and back-flow preventer when required by local code.
GAS REQUIREMENTS
(GAS TYPE MUST BE SPECIFIED ON ORDER)
RATED THERMAL LOAD
NORTH AMERICA
Natural Gas/Propane
Gross Heating Value (HHV)
98,000 Btu / hr
ELECTRICAL - CTP7-20G
(DEDICATED CIRCUIT REQUIRED)
VOLTAGE
PH
HZ
120
1
60
 
v
208 – 240
50/60
1
 
¦
v
208 – 240
3
50/60
 
v
380 – 415
3
50/60



NORTH AMERICA VOLTAGE CHOICE
GROUND FAULT OR RESIDUAL CURRENT PROTECTION DEVICE MUST ACCOMMODATE A LEAKAGE CURRENT OF
,
PER UL REQUIREMENTS
MUST BE PERMANENTLY CONNECTED TO ELECTRICAL SUPPLY SOURCE
v
WEIGHT
NET
660 lbs
EST
SHIP
728 lbs*
SHIP DIMENSIONS
(L x W x H) 56" x 49" x 51"*
(1422mm x 1245mm x 1295mm)*
*
DOMESTIC GROUND SHIPPING INFORMATION
24
MN-35947
# 4 3 3 - 1 0 / 1 6
46-3/16" (1173mm)
D
A, B
E
30-13/16" (783mm)
1-11/16" (42mm)
IP X5
3/4" NPT*
* Both inlets can be from same 3/4" source.
Divide using a manifold. Run one side through
treatment device before running to oven.
VERTICAL VENT TO EXTEND ABOVE THE EXHAUST
200°F (93°C).
18" (457mm)
RECOMMENDED SERVICE ACCESS
2" (51mm)
DOOR SWING OR
COMBUSTIBLE SURFACES
BOTTOM: 5-1/8" (130mm)
FOR LEGS, AIR INTAKE
• Hood installation is required.
INTERNATIONAL
G20, G25, G31
Net Heating Value (LHV)
26.5 kW
CONNECTION
AWG (mm
)
2
no cord, no plug
12 (3.31)
L1, N, G
14 (2.08)
L1, L2/N, G
14 (2.08)
L1, L2, L3, G
14 (2.08)
L1, L2, L3, N, G
PAN CAPACITY
FULL–SIZE:
300 kg
GN 1/1:
GN 2/1:
330 kg*
**FULL–SIZE SHEET:
PRODUCT CAPACITY
PRODUCT MAXIMUM
VOLUME MAXIMUM
.
CONTACT FACTORY FOR EXPORT WEIGHT AND DIMENSIONS
Rev 12
11/16
d u e t o o n G o i n G p r o d u c t i m p r o v e m e n t
A= UNTREATED WATER
B= TREATED WATER
C= ELECTRICAL
D= GAS
E= WATER DRAIN
D
B
A
E
C
2-5/16" (58mm)
3-3/16" (81mm)
4-3/16" (106mm)
4-7/8" (124mm)
DIMENSIONS: H x W x D
EXTERIOR:
37-13/16" x 43-3/4" x 46-3/16" (961mm x 1111mm x 1173mm)
EXTERIOR WITH RECESSED DOOR:
37-13/16" x 48-3/4" x 46-3/16" (961mm x 1238mm x 1173mm)
INTERIOR:
23-1/4" x 24-1/4" x 32-3/4" (590mm x 616mm x 832mm)
WATER QUALITY STANDARDS
It is the sole responsibility of the owner/operator/purchaser of this equipment
to verify that the incoming water supply is comprehensively tested and if
required, a means of "water treatment" provided that would meet compliance
requirements with the published water quality standards shown below.
Non-compliance with these minimum standards will potentially damage this
equipment and/or components and void the original equipment manufacturer's
warranty. Alto-Shaam recommends using OptiPure
products to properly treat your water.
Total Dissolved Solids (tds)
HOOK-UP: 3/4" NPT
CONNECTED PRESSURE
NORTH AMERICA
Natural Gas
Minimum: 5.5" W.C. dynamic
Minimum: 9" W.C. dynamic
Maximum: 14" W.C. static
Maximum: 14" W.C. static
AMPS
BREAKER
kW
6.8
20
.84
4.8 – 4.2
15
1.0
4.8 – 4.2
15
1.0
4.6 – 4.2
15
1.0
20mA
STANDARD MODEL
20" x 12" x 2-1/2"
Sixteen (16)
530 x 325 x 65mm
Sixteen (16)
650 x 530 x 65mm
Eight (8)
18" x 26" x 1"
Eight (8)
.
**
ON WIRE SHELVES ONLY
Combitherm® CT PROformance™ and CT Classic Series Installation Manual
,
s p e c i f i c a t i o n s a r e s u b j e c t t o c h a n G e w i t h o u t n o t i c e
CTP7-20G
Gas boiler
6-11/16" (168mm)
4-1/4" (108mm)
A, B, D, E
C - at bottom
of oven
47-7/16" (1205mm)
®
[www.optipurewater.com]
Contaminant
Inlet Water Requirements
Free Chlorine
Less than 0.1 ppm (mg/L)
Hardness
30-70 ppm
Chloride
Less than 30 ppm (mg/L)
pH
7.0 to 8.5
Silica
Less than 12 ppm (mg/L)
50-125 ppm
INTERNATIONAL
Propane
WITH COMBISMOKER
CONNECTION
AMPS
BREAKER
no cord, no plug
L1, N, G
12.0
L1, L2/N, G
7.3 – 7.1
L1, L2, L3, G
7.3 – 7.1
L1, L2, L3, N, G
7.2 – 7.1

¦
INTERNATIONAL VOLTAGE CHOICE
ELECTRICAL SERVICE CHARGE APPLIES
WITH COMBISMOKER
Fifteen (15)
Fifteen (15)
Seven (7)
Eight (8)
168 lb (76 kg)
105 quarts (133 liters)
.
ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
.
7.20 GAS
-
free
G20
20mbar (2kPa)
G25
20mbar (2kPa)
G31
30mbar (3kPa)
®
OPTION
kW
20
1.5
15
1.5 – 1.7
15
1.5 – 1.7
15
1.6 – 1.7
®
OPTION
.
-
.
w w w
a l t o
s h a a m
c o m

Advertisement

Table of Contents
loading

Related Products for COMBITHERM CTP10-20E

Table of Contents