Electrical Kit Installation - 60 Hz - COMBITHERM CTP10-20E Installation Manual

Hide thumbs Also See for CTP10-20E:
Table of Contents

Advertisement

Installation
E L E C T R I C A L K I T I N S T A L L AT I O N – 6 0 H z
Applications
for the
Americas
Note: Cabling and
connectors must be supplied
for 120V configurations.
1
A
Remove enough cable covering so that wires reach the terminal strip.
2
Depending on the application, install the straight or elbow fitting to the cable.
Cut threads into nut before installing fitting.To do so, apply a
light lubricant and thread nut on and off fitting.
2*
B
1
* For 3-phase appliances remove white wire.
* For 1-phase appliances remove red wire and orange wire.
Cut threads into nut before installing fitting.To do so, apply a
light lubricant and thread nut on and off fitting.
B
2
2*
* For 3-phase appliances remove white wire.
* For 1-phase appliances remove red wire and orange wire.
Strip the wires, then connect them to the terminal strip.
6
Note:
Illustrations are representative only. Your appliance may vary.
1/2"
(12mm)
44
MN-35947
B
B
Appliance side
1
2
3
A
Power supply side
1
2
3
1
3
4
5
4
1
3
4
5
5
L1
GND
L2/N
BK
GR
WH
GND
L1 L2/N
BK WH GR
Rev 12
11/16
Combitherm® CT PROformance™ and CT Classic Series Installation Manual
Discard the cover plate if applicable.
Position and attach the support plate (x).
x
x
Install the fitting/wiring to the appliance.
1-1/2" NPT and smaller bushings through the
bottom, all others through the back.
Installation point for
1-1/2" NPT and
smaller 90º bushings.
Route the wires. Keep wires away from hot surfaces such as water tank,
drain pipe, motor, edges of sheet metal, vent pipes, or other appliances.
120V
1Ph
BK RD
208-240V
3Ph
208-240V
1Ph
380-415V
3Ph
x
OR GR
GND
PE
L1
L2 L3
GR
BK RD WH

Advertisement

Table of Contents
loading

Related Products for COMBITHERM CTP10-20E

Table of Contents