Gas Supply & Installation - COMBITHERM CTP10-20E Installation Manual

Hide thumbs Also See for CTP10-20E:
Table of Contents

Advertisement

Installation
g A S S u p p LY A N D I N S T A L L AT I O N
WARNINg
To prevent SERIOUS INjURy or dEATH from
fire or explosion:
Only connect the type of gas indicated on the
identification nameplate. your gas Combitherm
equipped to operate using only the fuel type specified
on the identification name plate. Should conversion
from natural gas to propane or from propane to
natural gas be desired, conversion parts must be
ordered from Alto-Shaam. Conversions must be
Alto-Shaam authorized service
peformed by an
provider only.
Always ensure the oven's nameplate
reflects the intended fuel type for your oven.
Residential gas connections and hard-piped gas
connections dO NOT meet NSF certifications and
should NEVER be used with your Combitherm oven.
Please refer to model specifications for rated
thermal loads and connected pressure requirements.
Natural
GR
CY
ES/FR/GB/IE/CH
AT
BE
DE
NL
Butane/Propane Mixture Cat
GR
CY
ES/FR/GB/IE/CH
AT
BE
DE
NL
AUS/NZ
AUS/NZ
Japan
Japan
46
MN-35947
is
®
Cat
Gas Type
II 2H3B/P
2H-G20-20mbar
II 2H3B/P
2H-G20-20mbar
II 2H3P
2H-G20-20mbar
II 2H3B/P
2H-G20-20mbar
II 2E(S)3B/P 2H-G20-20mbar
II 2ELL3B/P 2E-G20/G25-20mbar
II 2L3B/P
2L-G25-25mbar
Gas Type
II 2H3B/P
3B/P-G30/G31-30mbar
II 2H3B/P
3B/P-G30/G31-30mbar
II 2H3P
3P-G31-30mbar
II 2H3B/P
3B/P-G30/G31-50mbar
II 2E(S)3P
3P-G31-30mbar
II 2ELL3B/P 3B/P-G30/G31-50mbar
II 2L3B/P
3B/P-G30/G31-30mbar
NGN 1.37 kPa
LPG-X Propane 2.75 kPa
Natural Gas 13A 1.96 kPa
LPG - Propane 2.8 kPa
Rev 12
11/16
Combitherm® CT PROformance™ and CT Classic Series Installation Manual
Installation shall comply with local codes required
for gas appliances. In the absence of local codes,
installation shall comply with the latest edition of:
USA: National Fuel Gas Code, ANSI Z223.1 (NFPA
54). And OSHA Regulations
Canada: Natural Gas and Propane Installation
Code, CAN/CSA-B149.1-15
EU: European Standard EN203
Australia/New Zealand: AS 5601
NOTICE: Connection components not supplied by
Alto-Shaam must comply with the regulations
in force of the country of use.
SEDImENT TRAp REQuIRED:
A sediment trap shall be installed
downstream of the appliance shutoff
valve as close to the inlet of the
appliance as practical at the time of
appliance installation. The sediment
trap shall be either a tee fitting with
a capped nipple in the bottom outlet,
as illustrated below or another device
recognized as an effective sediment
trap.
To
equipment
inlet
Gas supply inlet
Tee fitting
80mm
Nipple
minimum
Cap

Advertisement

Table of Contents
loading

Related Products for COMBITHERM CTP10-20E

Table of Contents