Standard I/O Signal
Assignment Table (PNP)
Table 2-2: Specific Output (Handling)
Logical
Output Name / Function
Number
30010
RUNNING
This signal signifies that the job is running. (Signifies that the job is running, system
status is waiting reserved start, or test run is running.) This signal status is the same
status as [START] in the programming pendant.
30011
SERVO IS ON
This signal signifies that the servo power is turned ON, internal processing such as
current position creation is complete, and the system is able to receive the START
command. This signal turns OFF when the servo power supply turns OFF. It can be
used for DX100 status diagnosis for an external start.
30012
TOP OF MASTER JOB
This signal signifies that the execution position is the top of the master job. This signal
can be used to confirm that the master job has been called.
30013
ALARM/ERROR OCCURRED
This signal signifies that an alarm or an error occurred. If a major error occurs, this
signal remains ON until the main power is turned OFF.
30014
BATTERY ALARM
This signal turns ON to notify that the battery requires replacing when the voltage
drops from the battery for backup memory of the encoder. Major problems may result
if memory data is lost because of an expired battery. It is recommended to avoid these
problems by using this signal as a warning signal.
30015 to
REMOTE/PLAY/TEACH MODE SELECTED
30017
This signal notifies the current mode setting. These signals are synchronized with the
mode select switch in the programming pendant. The signal corresponding to the
selected mode turns ON.
30020
IN CUBE 1
This signal turns ON when the current TCP lies inside a pre-defined space (Cube 1).
Use this signal to prevent interference with other manipulators and positioners.
30021
IN CUBE 2
This signal turns ON when the current TCP lies inside a pre-defined space (Cube 2).
Use this signal to prevent interference with other manipulators and positioners.
30022
WORK HOME POSITION (IN CUBE 32)
This signal turns ON when the current TCP lies inside the work home position area.
Use this signal to evaluate whether the manipulator is in the start position.
30023
INTERMEDIATE START OK (Sequence Continuing)
This signal turns ON when the manipulator operates. It turns OFF when the currently
executed line is moved with the cursor or when editing operation is carried out after
HOLD is applied during operation. Therefore, this signal can be used as a restart
interlock after a HOLD is applied. However, it also turns ON in the teach mode and
TEACH MODE SELECTED signal must be referred together.
30050 to
HAND VALVE 1-4
30057
These outputs are controlled by the HAND handling specific instructions.
Hand valves 1 to 4 correspond to HAND 1 to 4.
1 This signal is not output during operation.
2 The work home position cube and Cube 32 are the same.