Table 3-1: Specific Input (General application)
Logical
Input Name / Function
Number
20010
EXTERNAL START
Functions the same as the [START] button in the programming pendant. Only the
rising edge of the signal is valid. It starts robot operation (playback). This signal is
invalid if external start is prohibited from the playback condition display.
20012
CALL MASTER JOB
Only the rising edge of the signal is valid. It calls up the top of the robot program, that
is the top of the master job
and when play master or call is prohibited (set from the playback operation condition
display).
20013
ALARM/ERROR RESET
After an alarm or error has occurred and the cause been corrected, this signal resets
the alarm or error.
20015
SELECT PLAY MODE
The play mode is selected when the mode key on the programming pendant is set at
"REMOTE". Only the rising edge of the signal is valid. When this selection signal
assigned concurrently with other mode selection signal, the teach mode is selected on
a priority basis. The signal is invalid while EXTERNAL MODE SWITCH is prohibited.
20016
SELECT TEACH MODE
The teach mode is selected when the mode key of the programming pendant is set at
"REMOTE". The other mode selection is unavailable when this signal is ON; the
signal is selected by priority even when the other selection signal is ON, enabling the
teach mode selection.
20020
INTERFERENCE 1 ENTRANCE PROHIBITED
If the manipulator attempts to enter the cube 1
manipulator goes to wait status (with servo power ON). During wait status, the
manipulator operation restarts if this signal turns OFF.
20021
INTERFERENCE 2 ENTRANCE PROHIBITED
If the manipulator attempts to enter the cube 2
manipulator goes to wait status (with servo power ON). During wait status, the
manipulator operation restarts if this signal turns OFF.
20022
WORK PROHIBITED (Tool ON Prohibited)
Even if TOOLON instruction is executed, the DX100 doesn't output to external while
this signal is ON.
20024
INTERFERENCE 3 ENTRANCE PROHIBITED
If the manipulator attempts to enter the cube 3
manipulator goes to wait status (with servo power ON). During wait status, the
manipulator operation restarts if this signal turns OFF.
20025
INTERFERENCE 4 ENTRANCE PROHIBITED
If the manipulator attempts to enter the cube 4
manipulator goes to wait status (with servo power ON). During wait status, the
manipulator operation restarts if this signal turns OFF.
1 A master job is a job (program) which can be called by CALL MASTER JOB.
Other functions are the same as for normal jobs. Normally, the parent job, which manages the child jobs called
up immediately after the power is turned ON, is set as the master job.
2 See section 8.6 "Interference Area" in the "DX100 INSTRUCTIONS ."
3
General Application
1)
. This signal is invalid during playback, during teach-lock
3-5
2)
area while this signal is ON, the
2)
area while this signal is ON, the
2)
area while this signal is ON, the
2)
area while this signal is ON, the
HW1480185
27 of 37

Advertisement

Table of Contents
loading

Table of Contents