5. Carefully lift the front panel away from the device.
Wiring Connector
on Thor VM3
6. Position the replacement front panel so wiring connector on the back of the front panel lines up with the connector on
the Thor VM3.
7. Gently press the front panel into place.
8. Tighten the sixteen (16) captive M3 screws. In the order shown in the top figure above, use a #2 Phillips bit and torque
the screws to 7 ± 0.5 inch pounds.
9. Reinstall the Thor VM3 in the Smart Dock.
10. When the Thor VM3 is placed in the powered dock, the UPS battery automatically reconnects.
11. Restart the Thor VM3.
12. If adding or removing a defroster, update the Thor VM3 configuration by selecting Start > Settings > Control Panel >
Peripherals and tap the Test button.
13. Close any open control panel windows.
14. Perform a touch screen
15. The Thor VM3 is ready for use.