Disconnect Ups Battery - Honeywell Thor vm3 User Manual

Venichle mount computer with microsoft windows embedded compact 7/0
Hide thumbs Also See for Thor vm3:
Table of Contents

Advertisement

Disconnect UPS Battery

CAUTION - The UPS battery must be disconnected before you ship the Thor VM3 or
Equipment Required
The following equipment is user-supplied:
• Torquing tool capable of measuring inch pounds
• #2 Phillips screwdriver bit
Disconnect Procedure
1. For convenience, the Thor VM3 can be removed
from the Smart Dock, though it is not necessary.
2. If the Thor VM3 remains in the dock, disconnect
the power cable from the dock.
3. Place the Thor VM3 in Suspend by pressing the
Power button.
4. Place the Thor VM3 face down on a stable
surface.
5. Use a #2 Phillips bit to loosen the captive M3
screws on the access panel with the mSATA and
SIM labels. This panel is on the right hand side
when the Thor VM3 is face down with the top
away from the user.
6. Locate the small push button located just below the SIM card installation slot.
7. Press the push button to disconnect the UPS. The UPS battery maintains its charge but is
disconnected from the power circuitry of the Thor VM3.
8. Reattach the access panel, torquing the M3 screws to 7.0 ± 0.5 inch pounds using a #2 Phillips
bit.
9. When the Thor VM3 is attached to external power, the UPS battery is automatically
reconnected.
10. Restart the Thor VM3.
Replace Front Panel
(page 4-53).
4 - 49

Hide quick links: