8.3.5 Auto-detect LVAL-sync / a-sync. accumulation

This function replaces the manual setting found in older JAI cameras. Whether accumulation is
synchronous or a-synchronous in relationship to LVAL depends on the timing of the trigger input.
When trigger is received while FVAL is high (during readout), the camera works in LVAL-
synchronous mode, preventing reset feed trough in the video signal. There is a maximum jitter of
one LVAL period from issuing a trigger and accumulation start.
If trigger is received when FVAL is low, the cameras works in LVAL-asynchronous mode (no delay)
mode. This applies to both pre-select (PS) trigger mode and pulse width trigger (PW) mode.
Ext. trigger
FVAL
(1) In this period camera executes trigger at next LVAL (prevents feed-through noise)
(2) Avoid trigger at FVAL transition (+/- 1 LVAL period), as the function may randomly switch
between "next LVAL" and "immediate".
(3) In this period camera executes trigger immediately (no delay)
Fig. 17. Auto-detect LVAL sync /a-sync accumulation

8.3.6 Rear panel indicator.

The rear panel mounted LED provides the following information:
Amber: Power connected - initiating
Steady green: Camera is operating in Continuous mode
Flashing green: The camera is receiving external trigger
Ethernet Connector indicates,
Steady Green: 1000 Base-T has been connected
Flashing green: 100 Base-T has been connected (Note)
Flashing amber: Network active in communication
Note: When 10 Base-T is connected, the green is flashing.
However, the video is not streamed through Ethernet.
CM-140 GE / -RA/-UV / CB-140GE/-RA
(1)
(2)
- 33 -
(3)
Fig.18. Rear Panel