Lval_Sync Timing; Lval_A-Sync Timing - IAI cm-140ge User Manual

Digital monochrome/color progressive scan gege vision camera
Table of Contents

Advertisement

8.5.2 Edge Pre-Select trigger mode
An external trigger pulse initiates the capture, and the exposure time (accumulation time) is the
fixed shutter speed set by registers. The accumulation can be LVAL synchronous or LVAL a-
synchronous. The resulting video signal will start to be read out after the selected shutter time.
For timing details, refer to fig. 20. through fig. 25.
To use this mode:
Set function:
Input:
Important notes on using this mode
Trigger pulse >2 LVAL to <1 FVAL)
The following table shows minimum trigger interval in synchronous accumulation mode
Full scan
1/2 Partial
2/3 partial
1/4 Partial
1/8 Partial
1/2 V Binning
In case of a-synchronous mode, the exposure time should be added to the above table.

LVAL_sync timing

LVAL_a-sync timing

CM-140 GE / -RA/-UV / CB-140GE/-RA
Trigger mode
Scanning
Vertical binning
Shutter mode
Exposure time Shutter speed, Programmable exposure
Other functions and settings
Ext. trigger.
Fig. 26. Edge Pre-select LVAL sync Timing
Edge Pre-Select (EPS)
Full, Partial
ON / OFF
Preset, Programmable, Abs
GigE interface or 12-pin Hirose
1055 L
821 L
705 L
531 L
445 L
530 L
- 39 -