3.1.1 Power ON

Before turning on all power switches of JUE-87, confirm that all the signal cables and power cables
are connected correctly.
Step
Operation/Response (Example)
• Turn on the DC switch and AC switch on the
1
EXT PSU.
• Turn on the IME and the POWER LED of
the IME is illuminated.
• The software version is displayed and
operation check.
• The IME system software starts up in about
2
30 seconds,
then Main menu screen is displayed.
• Turn on the printer.
3
• The
status
"Egc-only" to "Tune" in the first line on the
main menu, then JUE-87 is started selecting
NCS common channel.
• After few minutes, the status is changed Tune
4
to "Comm (TX)" or "Egc-only" in the first
line on the main menu.
• After few minutes, READY LED on the IME
is lit.
• The status is changed "Comm (TX)" to
"READY" in the first line on the main menu.
• Set up each parameter following "3.5 Initial
5
setting".

3.1.2 Power OFF

Turn OFF the power switch of JUE-87 with below outlined procedure.
Step
Operation/Response (Example)
• Turn off the IME.
1
(Press the POWER button until
POWER LED starts blink.)
• The status is changed "READY" to "Comm (TX)"
2
in the first line on the main menu to initiate the
Log-out.
• After few minutes,
light OFF.
• When "Log-out", "Egc-only" or "Tune" is
displayed in the first line on the main menu, power
supply of IME is turned off automatically.
• Turn off the printer.
3
• Turn off the DC switch and AC switch on the
EXT PSU.
is
changed
"Log-out"
LED on the IME is
POWER
NOW LOADING・・・
SELF DIAGNOSING・・・
Software version
ROM c heck
RAM check
Keyboard check
See "Fig. 3.4"
or
Log-in (10-11-04 12:05) succeeded.
• Press "Power" on front of IME for 2
seconds at least.
• When you turned off the external
power switch, IME is turned off
without Log-out. Switch off after
check whether it has Log-out.
• Switch off the external power source
from DC switch to AC switch.
If you made reverse this turn, the
power failure detection circuit works
after turn off the AC switch, and the
battery is drained until turn off the
DC switch.
3-2
Screen (Example)
:1.00
: OK
:OK
:OK
F10:Previous
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents