Ext Psu (Nbd-904) - JRC jue-87 Instruction Manual

Hide thumbs Also See for jue-87:
Table of Contents

Advertisement

5.1.3 EXT PSU (NBD-904)

Item
Line voltage
Line voltage range
Line frequency range
Function
Control Signal
Output
Switch
LED
Protection
Others
Dimensions
Weight
Table 5.1.3 Principal Specification of EXT PSU
AC: from +100V to +220V /DC: +24V
AC:+89V to +266V/ DC:+19.2 to +31.2V
47 Hz to 64Hz
DC power automatic backup at AC power failure
DC input is only available when AC input is stopped.
DC output is only supplied through DC input (condition: over
+18V and "REMOTE CONT" is short).
REMOTE CONT +/- (Input): When open, DC input is not
available, when short, DC input is available.
AC FAIL +/- (Output): When AC input is stopped, between + and
– is open, when AC input is available, between + and – is short.
(Output rating: DC 30V, 30mA)
Floating type DC+24V, 8.5A (max, 5minutes) 6.5A (Continuous)
DC INPUT: turn on/off DC input + line.
DC OUTPUT: turn on/off DC output +/- line
AC operation is lighted up, when AC input available.
DC operation is lighted up, when DC output is supplied through
DC input.
DC output is lighted up, when DC output is available.
Protection by No-Fuse breaker or Fuse (DC over current only)
Over voltage (Input) +35V DC , +280V AC
(Automatic protected. => Protected is removed after turn off/on.)
Over current (Output) 13.0A (AC.. automatic), 15.0A (DC ... Fuse)
Isolation against ground: > 1M ohm at DC 500V
Temperature: Compatible with IEC 60945
Fuse: DC32V, 15A (DC+/- input)
168 mm(W) × 250 mm(D) × 98 mm(H)
2.6 kg
5-3
Specification