2. FUNCTION SETTINGS (OPERATION PANEL)
Standard device settings (550-)
Setting
No.
range
F550
0 - 1
0 - 500
F551
(ms)
-345 - 345
F555
(degrees)
(degrees)
-345 - 345
F556
(degrees)
(degrees)
-345 - 345
F557
(degrees)
(degrees)
-345 - 345
F558
(degrees)
(degrees)
10 - 200
F560
(ms)
10 - 200
F561
(ms)
10 - 200
F562
(ms)
10 - 500
F563
(ms)
0 - 240
F564
(seconds)
(seconds)
10 - 60
F565
(%)
10 - 60
F566
(%)
F567
0 - 1
20 - 120
F568
(ms)
F569
10 - 15
40 - 100
F573
(ms)
10 - 60
F574
(%)
(*1) This is not initialized during initialization mode.
15
Initial
Setting
value
units
Automatic presser foot lifter type
0: Solenoid type
0
1
(*1)
1: Pneumatic type
150
10
Sewing machine motor start delay time when presser foot is raised
(ms)
(ms)
0
Quick reverse solenoid on timing during start backtacking/continuous
1
backtacking
0
Quick reverse solenoid off timing during start backtacking/continuous
1
backtacking
0
1
Quick reverse solenoid off timing during end backtacking
0
Quick reverse solenoid on timing during end backtacking
1
* This is only enabled when F451 is set to "ON".
Thread wiping and presser foot lift operation timing after thread trimming
20
10
(ms)
(ms)
50
10
(ms)
(ms)
Presser foot lifting
50
10
(ms)
(ms)
300
10
Presser foot lifter solenoid fully ON time
(ms)
(ms)
Presser foot lift time
180
1
0: No timer function (does not drop)
1-240: Presser foot drops after set time.
25
On duty when solenoid-type presser lifter solenoid is chopping
1
(%)
* This is only enabled when F550 is set to "0".
50
On duty when pneumatic-type presser lifter solenoid is chopping
1
(%)
* This is only enabled when F550 is set to "1".
Presser foot soft down mode
0: Automatic mode (This can be adjusted using F569.)
0
1
1: Manual mode (This must be adjusted using F568.)
Delay time for presser foot lifter solenoid to turn on after presser foot drop
40
5
command
(ms)
(ms)
* This is only enabled when F567 is set to "1".
Voltage detection constant for presser foot lifter solenoid to turn on after
presser foot drop command
12
1
* This is only enabled when F567 is set to "0". If it is set to "10", the
85
5
Fully on time for quick reverse solenoid
(ms)
(ms)
60
1
On duty when quick reverse solenoid is chopping
(%)
(Duty during chopping can be changed using F565.)