Brother S-7000DD Service Manual page 17

Single needle direct drive straight lock stitcher with thread trimmer
Hide thumbs Also See for S-7000DD:
Table of Contents

Advertisement

Sewing machine motor settings (100-)
Setting
Initial
No.
range
value
1-99
F100
(needles)
(needles)
F101
OFF/1-3
F102
1-5
Sewing machine motor settings (150-)
Setting
No.
range
F150
ON/OFF
OFF/
F151
1-2
F152
ON/OFF
10 - 500
F153
(ms)
-20 - 20
F154
(degrees)
(degrees)
F155
0
F156
ON/OFF
-20 – 20
F157
(degrees)
Setting
units
2
1
Number of slow start stitches
Pedal response switching settings immediately after sewing has started
OFF: No switching
OFF
1
1: Slow start only when sewing starts after thread trimming
2: Slow start only when sewing starts after sewing has been paused
3: Slow start always when sewing starts
Pedal response immediately after sewing has started
1
1
* The larger the value, the slower the speed when sewing starts.
* If F101 is set to "OFF", this setting is disabled.
Initial
Setting
value
units
Slow stop control when treadle is returned to neutral
ON: Slow stop control without step operation
ON
-
OFF: Above control is not used.
Effective hammer operation
OFF: No operation
1
1
1: Only operates when needle does not pierce
2: Operates when needle does not pierce and during thread trimming
Highest needle position stop operation
* This is disabled when F156 is set to "ON".
OFF
-
ON: Used
OFF: Not used
Delay time until reverse operation starts during highest needle position
150
10
stop operation
(ms)
(ms)
* This is only enabled when F156 or F152 is set to "ON".
Quick reverse needle up stop position setting
* This is only enabled when F156 is set to "OFF" and F152 is set to "ON".
* The reverse operation angle is 40° to 80°.
0
1
Thread wiping operation and presser foot lifting operation during highest
needle position stop operation
* This is only enabled when F152 is set to "ON".
1
1
0: The needle is raised, then thread wiping is carried out, and then the
Reverse needle lifting operation 2
* This operation has priority over the setting for F152, and makes the
OFF
-
ON: Enabled
OFF: Disabled
Reverse operation needle up stop position 2 setting
* This is only enabled when F156 is set to "ON".
* The reverse operation angle is 80° to 120°.
0
1
2. FUNCTION SETTINGS (OPERATION PANEL)
(Low speed operating time before sewing stops is almost constant)
(Low speed operating time before sewing stops is not constant.)
Becomes lower
presser foot is lifted.
reverse operation angle larger.
Reverse operation increases
S-7000DD
Setting details
Setting details
Becomes higher
Reverse operation decreases
(Continued on next page)
2248M
8

Advertisement

Table of Contents
loading

Table of Contents