Fault Messages In The Display - Miele PW 5064 MopStar 60 Operating And Installation Instructions

Hide thumbs Also See for PW 5064 MopStar 60:
Table of Contents

Advertisement

Problem solving guide

Fault messages in the display

Message in the display
p
Water inlet fault
,
Technical fault.
Call Service
,
Fault
Disinfection temp.
not
reached
o
Waterproof system
has reacted
q
Drainage fault
Fill the dispensing
container
I
or
Fault
Container empty
A To switch off the fault message, press the OK button.
42
Possible cause
The water inlet is
blocked or restricted.
The water pressure is
too low.
There is a fault.
During the disinfection
programme the water
temperature was not
reached.
The water protection
system has reacted.
The water outlet is
blocked or restricted.
One of the external
detergent containers
is empty.
Remedy A
Check whether
– the stopcock is opened
wide enough.
– the inlet hose is kinked.
– Select Low water
pressure in the Settings/
Supervisor level menu.
Start the programme again.
If the fault message appears
again, contact the Service
Department.
The machine has not
carried out the disinfection
cycle correctly.
Start the programme again.
– Close the stopcock.
– Call the Service
Department.
Call the Service Department.
See "Detergent - Empty
sensor".