Cisco ME 3800X and ME 3600X Switch Cisco IOS Commands
For physical interfaces:
When you define a range, you must enter a space before the hyphen (-), for example:
gigabitethernet0/1 - 2
You can also enter multiple ranges. When you define multiple ranges, you must enter a space after the
first entry before the comma (,). The space after the comma is optional, for example:
gigabitethernet0/3, tengigabitethernet0/1 - 2
gigabitethernet0/3 -4, tengigabitethernet0/1 - 2
Examples
This example shows how to create a multiple-interface macro:
Switch(config)# define interface-range macro1 fastethernet0/1 - 2, gigabitethernet0/1 - 2
Related Commands
Command
interface range
show running-config
OL-28238-01
module is always 0.
the range is type 0/number - number (for example, gigabitethernet 0/1 - 2).
Description
Executes a command on multiple ports at the same time.
Displays the operating configuration.
Cisco ME 3800X and ME 3600X Switch Command Reference
define interface-range
2-53