Chapter 2
Cisco ME 3800X and ME 3600X Switch Cisco IOS Commands
network-clock revertive
To configure the Synchronous Ethernet (SyncE) input clock to determine the action to take if clock
reference with higher priority than the selected reference clock becomes available, use the network-clock
revertive command in global configuration mode. To return to the default value, use the no form of this
command.
Syntax Description
This command has no arguments or keywords.
Defaults
The default is non-revertive.
Command Modes
Global configuration
Command History
Release
15.1(2)EY
Usage Guidelines
The network clock can be selected by an automatic selection algorithm based on the highest priority
valid input clock. In revertive mode, the network clock is automatically selected reference based on the
configured priority of the clock.
Examples
The following example shows how to configure the network-clock as revertive.
Switch# configure terminal
Switch(config)# network-clock revertive
Related Commands
Command
show network-clocks
show network-clock
synchronization
controller BITS
commands
OL-28238-01
network-clock revertive
no network-clock revertive
Modification
This command was introduced.
Description
Displays network clock configuration.
Displays network clock configuration.
Configures the BITS clock controller characteristics.
Cisco ME 3800X and ME 3600X Switch Command Reference
network-clock revertive
2-189