Carel PRK300L3FK User Manual page 69

Prack pr300 no power & signal cables together read carefully in the text! compressor rack controller
Table of Contents

Advertisement

Mask index
Display description
Prop Gain:
Eid06
Integral time:
Derivat.time:
LowSH protect.:
Eid08
LOP protection:
MOP protection:
Threshold:
Eid10
Integr.time:
Alarm timeout
LowSH:
Eid11
LOP:
MOP:
Threshold
Eid13
Timeout
Valve A opening at
Eid15
start-up
Valve A opened in
stand-by
Eid17
Start-up delay after
defrost
Valve A preposit. delay
Prop Gain:
Eid19
Integral time:
Derivat.time:
LowSH protect.:
Eid21
LOP protection:
MOP protection:
Threshold:
Eid23
Integr.time:
Alarm timeout
LowSH:
Eid24
LOP:
MOP:
Threshold
Eid26
Timeout
Min.steps
Eie02
Max.steps
Closing steps
Min.steps
Eie04
Max.steps
Closing steps
Enable EVD in PLB x
EVD valves number
Eif01
EVS 1 Address
EVS 2 Address
Defaults:
Eif02
Force Parameters:
Regulation based on:
Eif03
Valve:
Main Regulation:
Eif05
Auxiliary regulation:
Eif06
Auxiliary refrigerant:
S1 probe alarm manag:
Eif09
S2 probe alarm manag:
Eif11
DC power supply
Description
Control proportional gain (valve 1)
Control integral time (valve 1)
Control derivative time (valve 1)
Integral time with low superheat protection (valve 1)
Integral time with low operating pressure protection (valve 1)
Integral time with maximum operating pressure protection (valve 1)
High condensing temperature protection activation threshold (valve 1) 30.0
Integral time with high condensing temperature protection (valve 1)
High condensing temperature alarm delay (valve 1)
Low superheat alarm delay (valve 1)
Low operating pressure alarm delay (valve 1)
Maximum operating pressure alarm delay (valve 1)
Low suction temperature protection threshold (valve 1)
Low suction temperature alarm delay (valve 1)
Valve opening at start of control (valve 2)
Enable valve opening with control not active (valve 2)
Start control delay after defrost (valve 2)
Stationary time when valve pre-positions (valve 2)
Control proportional gain (valve 2)
Control integral time (valve 2)
Control derivative time (valve 2)
Integral time with low superheat protection (valve 2)
Integral time with low operating pressure protection (valve 2)
Integral time with maximum operating pressure protection (valve 2)
High condensing temperature protection activation threshold (valve 2) 30.0
Integral time with high condensing temperature protection (valve 2)
High condensing temperature alarm delay (valve 2)
Low superheat alarm delay (valve 2)
Low operating pressure alarm delay (valve 2)
Maximum operating pressure alarm delay (valve 2)
Low suction temperature protection threshold (valve 2)
Low suction temperature alarm delay (valve 2)
Minimum step confi guration, valve 1
Maximum step confi guration, valve 1
Closing step confi guration, valve 1
Minimum step confi guration, valve 2
Maximum step confi guration, valve 2
Closing step confi guration, valve 2
Enable the EVD management on current board
Number of drivers managed
Serial address of driver 1
Serial address of driver 2
Run driver parameter setting procedure
Override driver parameter settings
Select cooling capacity used for control
Type of valve connected to the driver
Main control for the valve, for details refer to manual +0300005EN
Safety or auxiliary control
Refrigerant used for P -> T conversion of probe S3 with high condensing
temperature protection
Type of action in the event of probe S1 fault
Type of action in the event of probe S2 fault
Confi gure the type of power supply used for the driver
Default
15.0
150
5.0
10.0
10.0
20.0
0.5
600
300
300
600
-50.0
300
50
NO
10
6
15.0
150
5.0
10.0
10.0
20.0
0.5
600
300
300
600
-50.0
300
50
480
500
50
480
500
NO
1
198
199
NO
NO
LINE 1 COMP
CAREL EXV
R404 CON-
DENSER FOR
SUBCRITICAL
CO2
INVERSE HIGH
CONDENS.
TEMP.
PROTECTION
ON S3
R744
VALVE AT
FIXED POS.
VALVE AT
FIXED POS.
NO
69
ENG
UOM
Values
0.0...800.0
s
0...1000
s
0...1000
s
0.0...800.0
s
0.0...800.0
s
0.0...800.0
°C/°F
-60.0...200.0
s
0.0...800.0
s
0...18000
s
0...18000
s
0...18000
s
0...18000
°C/°F
-60.0...200.0
s
0...18000
%
0...100
NO/YES
min
0...60
s
0...18000
0.0...800.0
s
0...1000
s
0...1000
s
0.0...800.0
s
0.0...800.0
s
0.0...800.0
°C/°F
-60.0...200.0
s
0.0...800.0
s
0...18000
s
0...18000
s
0...18000
s
0...18000
°C/°F
-60.0...200.0
s
0...18000
0...9999
0...9999
0...9999
0...9999
0...9999
0...9999
NO/YES
1 / 2
0...207
0...207
LINE 1 COMP. / LINE 2 COMP
USER DEFINED / CAREL EXV
/ ALCO EX4 / ALCO EX5 /
ALCO EX6 / ALCO EX7 /
ALCO EX8 CAREL RECOM-
MENDED / ALCO EX8 ALCO
SPECIFICATION / SPORLAN SEI
0.5-11 / SPORLAN SER 1.5-20
/ SPORLAN SEI 30 / SPORLAN
SEI 50 / SPORLAN SEH 100 /
SPORLAN SEH 175 / Danfoss
ETS 12.5-25B / Danfoss ETS 50B
/ Danfoss ETS 100B / Danfoss
ETS 250 / Danfoss ETS 400 /
TWO CAREL EXV TOGETHER /
SPORLAN SER(I) G, J, K / Dan-
foss CCM 10-20-30 / Danfoss
CCM 40
Possible control functions in
manual +0300005EN
Possible control functions in
manual +0300005EN
NO ACTION / VALVE FORCE
CLOSED / VALVE AT FIXED POS
/ USE BACKUP S3
NO ACTION / VALVE FORCE
CLOSED / VALVE AT FIXED POS
/ USE BACKUP S4
NO / YES
pRack +0300025EN rel. 1.3 - 17.12.2015

Hide quick links: