Carel PRK300L3FK User Manual page 52

Prack pr300 no power & signal cables together read carefully in the text! compressor rack controller
Table of Contents

Advertisement

ENG
Mask index
Display description
A.Unit status
Pressure
Aa01
Sat.temp.
(display only)
Act.setpoint
Diff erential
Pressure
Sat.temp.
Aa02
Act.setpoint
(display only)
Diff erential
Actual/req.
Reg.status
Aa03
(display only)
Reg.type
Setpoint
C01, C02, ...C12
C01
Aa04
(display only)
...
C12
Aa05
Temperature
Superheat
(display only)
Disch.1
Aa11
...
(display only)
Disch.6
Liq.inj.1: DO
Aa13
...
(display only)
Liq.inj.6: DO
Discharge temperature
Cap.reduction
Aa15
Oil sump temp.
(display only)
Oil status
Status
Countdown
Aa16
Compr.
(display only)
Valve
Requested cap.
Current capac.
Pressure
Aa20
Sat.temp.
Act.setpoint
(display only)
Diff erential
Pressure
Aa21
Sat.temp.
Act.setpoint
(display only)
Diff erential
Actual/req.
Status
Aa22
(display only)
Reg.type
Setpoint
F1
Aa23
...
(display only)
F8
F9
Aa24
...
(display only)
F16
Aa25
Discharge temperature
External temperature
(display only)
Pressure
Aa31 (display
Sat.temp.
Act.setpoint
only)
Diff erential
Pressure
Aa32
Sat.temp.
(display only)
Act.setpoint
Diff erential
pRack +0300025EN rel. 1.3 - 17.12.2015
Description
Suction pressure (line 1)
Saturated suction temperature (line 1)
Eff ective set point for pressure control (with compensation applied, line 1)
Control diff erential for pressure control (line 1)
Suction pressure (line 1)
Saturated suction temperature (line 1)
Eff ective set point for temperature control (with compensation applied, line
1)
Control diff erential for temperature control (line 1)
Capacity delivered/capacity required for suction line (line 1)
Control status (according to the type of control set, line 1)
Compressor control type (line 1)
Eff ective suction pressure set point (with compensation applied, line 1)
Time remaining to next compressor start (line 1)
Capacity delivered by compressor 1 on line 1 (a ''!'' to the right of the value
means that some form of compressor capacity override is active, e.g. times,
alarms, start-up procedure)
...
Capacity delivered by compressor 12 (line 1)
Suction temperature (line 1)
Superheat (line 1)
Discharge temperature, compressor 1 (line 1)
...
Discharge temperature, compressor 6 (line 1)
Number of digital output associated and status of liquid injection/
economizer (*) compressor 1 (line 1)
...
Number of digital output associated and status of liquid injection/
economizer (*) compressor 6 (line 1)
Digital ScrollTM compressor discharge temperature (line 1)
Digital ScrollTM compressor capacity reduction in progress (line 1)
Digital ScrollTM compressor oil sump temperature (line 1)
Digital ScrollTM compressor oil dilution status (line 1)
Digital ScrollTM compressor operating status (line 1)
Digital ScrollTM compressor time count (line 1)
Digital ScrollTM compressor status (line 1)
Digital ScrollTM valve status(line 1)
Digital ScrollTM compressor capacity required (line 1)
Digital ScrollTM compressor eff ective capacity (line 1)
Condensing pressure (line 1)
Saturated condensing temperature (line 1)
Eff ective set point for pressure control (with compensation applied, line 1)
Control diff erential for pressure control (line 1)
Condensing pressure (line 1)
Saturated condensing temperature (line 1)
Eff ective set point for temperature control (with compensation applied, line 1) ... (**)
Control diff erential for temperature control (line 1)
Capacity delivered/capacity required for condenser line (line 1)
Control status (according to the type of control set, line 1)
Condenser control type (line 1)
Condenser control eff ective set point (with compensation applied, line 1)
Power output of fan 1 on line 1 (a ''!'' to the right of the value means that
some form of power override is active)
...
Power output of fan 8 on line 1 (a ''!'' to the right of the value means that
some form of power override is active)
Power output of fan 9 on line 1 (a ''!'' to the right of the value means that
some form of power override is active)
...
Power output of fan 16 on line 1 (a ''!'' to the right of the value means that
some form of power override is active)
Discharge temperature (line 1)
Outside temperature (line 1)
Suction pressure (line 2)
Saturated suction temperature (line 2)
Eff ective set point for pressure control (with compensation applied, line 2)
Control diff erential for pressure control (line 2)
Suction pressure (line 2)
Saturated suction temperature (line 2)
Eff ective set point for temperature control (with compensation applied, line 2) ... (**)
Control diff erential for temperature control (line 2)
Default
---
---
... (**)
... (**)
---
---
... (**)
... (**)
---
---
Neutral
zone
... (**)
---
---
...
---
---
---
---
...
---
---
...
---
---
---
---
---
---
---
---
---
---
---
... (**)
... (**)
---
---
... (**)
---
---
Neutral
zone
... (**)
---
...
---
---
...
---
---
---
---
---
... (**)
... (**)
---
---
... (**)
52
UOM Values
...
... (**)
...
... (**)
...
... (**)
...
... (**)
...
... (**)
...
... (**)
...
... (**)
...
... (**)
%
0/0 ...100/100
---
Stop Increas
Operating
Decrease
Timings
Standby
Alarms
---
Proportional band
Neutral zone
...
... (**)
s
0...32000
%
0...100
...
...
%
0...100
...
... (**)
...
... (**)
...
... (**)
...
...
...
... (**)
...
0...29
ON / OFF
...
...
...
0...29
ON / OFF
...
... (**)
NO / YES
...
... (**)
Ok
Dilute
---
Off
Off by time
Start up
On by time
On
Mod. manual
Alarm
In pump down
s
0...999
---
OFF
ON
---
OFF
ON
%
0...100
%
0...100
...
... (**)
...
... (**)
...
... (**)
...
... (**)
...
... (**)
...
... (**)
...
... (**)
...
... (**)
%
0/0 ...100/100
---
Stop
Operating
Increase
Timings
Decrease
Alarms
Stand-by
---
Proportional band
Neutral zone
...
... (**)
%
0...100
...
...
%
0...100
%
0...100
...
...
%
0...100
...
... (**)
...
... (**)
...
... (**)
...
... (**)
...
... (**)
...
... (**)
...
... (**)
...
... (**)
...
... (**)
...
... (**)