Carel PRK300L3FK User Manual page 68

Prack pr300 no power & signal cables together read carefully in the text! compressor rack controller
Table of Contents

Advertisement

ENG
Mask index
Display description
ID1 confi guration:
Eic08
ID2 confi guration:
DI1:
Eic09
DI2:
Eic10
Valve A relay confi g.:
Eic11
Valve B relay confi g.:
S1 off set
S1 probe (display)
Eic12
S2 off set
S2 probe (display)
S3 off set
S3 probe (display)
Eic13
S4 off set
S4 probe (display)
Alarm:
EN.
Type:
Eic14
Min.:
Max.:
Alarm min.:
Alarm max.:
Alarm:
EN.
Eic15
Type:
Alarm min.:
Alarm max.:
Alarm:
EN.
Type:
Eic16
Min.:
Max.:
Alarm min.:
Alarm max.:
Alarm:
EN.
Eic17
Type:
Alarm min.:
Alarm max.:
Eic18
ID1 confi guration:
ID2 confi guration:
DI1:
Eic19
DI2:
Eic20
Valve A relay confi g.:
Eic21
Valve B relay confi g.:
Valve A opening at
Eid02
start-up
Valve A opened in
stand-by
Eid04
Start-up delay after
defrost
Valve A preposit. delay
pRack +0300025EN rel. 1.3 - 17.12.2015
Description
Confi guration of action of digital input 1 on driver (valve 1)
Confi guration of action of digital input 2 on driver (valve 1)
Digital input 1 status (valve 1)
Digital input 2 status (valve 1)
Confi guration of digital output1 (valve 1)
Confi guration of digital output 2 (valve 1)
Probe S1 reading off set (valve 2)
Value read by probe S1 (valve 2)
Probe S2 reading off set (valve 2)
Value read by probe S2 (valve 2)
Probe S3 reading off set (valve 2)
Value read by probe S3 (valve 2)
Probe S4 reading off set (valve 2)
Value read by probe S4 (valve 2)
Enable probe S1 alarm (valve 2)
Type of probe S1 (valve 2)
Minimum probe S1 reading (valve 2)
Maximum probe S1 reading (valve 2)
Minimum probe S1 alarm threshold (valve 2)
Maximum probe S1 alarm threshold (valve 2)
Enable probe S2 alarm (valve 2)
Type of probe S2 (valve 2)
Minimum probe S2 alarm threshold (valve 2)
Maximum probe S2 alarm threshold (valve 2)
Enable probe S3 alarm (valve 2)
Type of probe S3 (valve 2)
Minimum probe S3 reading (valve 2)
Maximum probe S3 reading (valve 2)
Minimum probe S3 alarm threshold (valve 2)
Maximum probe S3 alarm threshold (valve 2)
Enable probe S4 alarm (valve 2)
Type of probe S4 (valve 2)
Minimum probe S4 alarm threshold (valve 2)
Maximum probe S4 alarm threshold (valve 2)
Confi guration of action of digital input 1 on driver (valve 2)
Confi guration of action of digital input 2 on driver (valve 2)
Digital input 1 status (valve 2)
Digital input 2 status (valve 2)
Confi guration of digital output1 (valve 2)
Confi guration of digital output 2 (valve 2)
Valve opening at start of control (valve 1)
Enable valve opening with control not active (valve 1)
Start control delay after defrost (valve 1)
Stationary time when valve pre-positions (valve 1)
Default
REG. BACKUP
DISABLED
---
---
ALARM RELAY
ALARM RELAY
0.0
---
0.0
---
0.0
---
0.0
---
EN./DIS.
4-20mA
-1.0
9.3
-1.0
9.3
EN./DIS.
CAREL NTC
-50.0
105.0
EN./DIS.
4-20mA
-1.0
30.0
-1.0
30.0
EN./DIS.
CAREL NTC
-50.0
105.0
REG. BACKUP
DISABLED
---
---
ALARM RELAY
ALARM RELAY
50
NO
10
6
68
UOM
Values
DISABLED / REG. SAFETY / REG.
BACKUP / START/STOP REG. /
VALVE FORCED 100% OPEN /
BATTERY ALARM MNG. / VALVE
REGULATION OPT. AFTER
DEFROST
DISABLED / REG. SAFETY / REG.
BACKUP / START/STOP REG. /
VALVE FORCED 100% OPEN /
BATTERY ALARM MNG. / VALVE
REGULATION OPT. AFTER
DEFROST
DISABLED / ALARM RELAY
/ SOLENOID VALVE RELAY /
VALVE + ALARM RELAY / RE-
VERSED ALARM RELAY / VALVE
POSITION RELAY
DISABLED / ALARM RELAY
/ SOLENOID VALVE RELAY /
VALVE + ALARM RELAY / RE-
VERSED ALARM RELAY / VALVE
POSITION RELAY
Barg/psig
Barg/psig
°C/°F
°C/°F
Barg/psig
Barg/psig
°C/°F
°C/°F
4-20mA / 4-20mA REMOTE /
4-20mA EXTERNAL / 0-5V RAT.
Barg/pisg -20.0...200.0
Barg/pisg -20.0...200.0
Barg/pisg -20.0...200.0
Barg/pisg -20.0...200.0
CAREL NTC / 0-10V EXT. SI-
GNAL / NTC SPKP**T0 / CAREL
NTC-HT
°C/°F
-60.0...200.0
°C/°F
-60.0...200.0
4-20mA / 4-20mA REMOTE /
4-20mA EXTERNAL / 0-5V RAT.
Barg/pisg -20.0...200.0
Barg/pisg -20.0...200.0
Barg/pisg -20.0...200.0
Barg/pisg -20.0...200.0
CAREL NTC / NTC SPKP**T0 /
CAREL NTC-HT
°C/°F
-60.0...200.0
°C/°F
-60.0...200.0
DISABLED / REG. SAFETY / REG.
BACKUP / START/STOP REG. /
VALVE FORCED 100% OPEN /
BATTERY ALARM MNG. / VALVE
REGULATION OPT. AFTER
DEFROST
DISABLED / REG. SAFETY / REG.
BACKUP / START/STOP REG. /
VALVE FORCED 100% OPEN /
BATTERY ALARM MNG. / VALVE
REGULATION OPT. AFTER
DEFROST
DISABLED / ALARM RELAY
/ SOLENOID VALVE RELAY /
VALVE + ALARM RELAY / RE-
VERSED ALARM RELAY / VALVE
POSITION RELAY
DISABLED / ALARM RELAY
/ SOLENOID VALVE RELAY /
VALVE + ALARM RELAY / RE-
VERSED ALARM RELAY / VALVE
POSITION RELAY
%
0...100
NO/YES
min
0...60
s
0...18000