Carel PRK300L3FK User Manual page 10

Prack pr300 no power & signal cables together read carefully in the text! compressor rack controller
Table of Contents

Advertisement

ENG
pRack pR300 D
10
J10
J1
1
Legende:
Ref.
Description
1
Power supply connector [G(+), G0(-)]
+Vterm: power supply for additional terminal
2
+5 VREF power supply for ratiometric probes
3
Universal inputs/outputs
4
+VDC: power supply for active probes
5
Button for setting pLAN address, second display, LED
VG: power supply at voltage A(*) for opto-isolated analogue output
6
VG0: power to opto-isolated analogue output, 0 Vac/Vdc
7
Analogue outputs
8
ID: digital inputs for voltage A (*)
9
ID..: digital inputs for voltage A (*); IDH..: digital inputs for voltage B (**)
10
pLAN telephone connector for terminal/downloading application
11
pLAN plug-in connector
12
Reserved
(*) Voltage A: 24 Vac or 28 to 36 Vdc; (**) Voltage B: 230 Vac - 50/60 Hz.
pRack pR300 L
10
J10
J1
1
Legende:
Ref. Description
1
Power supply connector [G(+), G0(-)]
+Vterm: power supply for additional terminal
2
+5 VREF power supply for ratiometric probes
5
Button for setting pLAN address, second display, LED
VG: power supply at voltage A(*) for opto-isolated analogue output
6
VG0: power to opto-isolated analogue output, 0 Vac/Vdc
7
Analogue outputs
8
ID: digital inputs for voltage A (*)
9
ID..: digital inputs for voltage A (*); IDH..: digital inputs for voltage B (**)
10
pLAN telephone connector for terminal/downloading application
(*) Voltage A: 24 Vac or 28 to 36 Vdc; (**) Voltage B: 230 Vac - 50/60 Hz.
pRack +0300025EN rel. 1.3 - 17.12.2015
13
14
11
12
J1 2
J11 pLAN
pR300
FieldBus c ar d
J24
J2
J3
5
2
3
4
3
11
12
13
14
J1 2
J11 pLAN
pR300
FieldBus c a rd
J24
J2
J3
2
3
4
3
5
15
J1 3
J1 4
J15
4
3
2
1
J2 5 BMS2
J26FBus2
17
16
18
22
J30
B M S c a r d
J4
J5
7
6
8
Fig. 2.c
Ref.
Description
13
Reserved
14
Reserved
15
Relay digital outputs
16
BMS2 connector
17
FieldBus2 connector
18
Jumpers for selecting FieldBus/ BMS
20
Electronic valve A connector
21
Electronic valve B connector
22
Connector for external Ultracap module (accessory)
23
Valve driver analogue and digital inputs
24
Valve status signal LED
15
J1 5
J1 3
J1 4
4
3
2
1
J2 1
J2 5 BMS2
J2 6 FBus2
16
17
18
15
9
J1 9
B M S c ar d
J4
J5
J6
6
7
8
3
Fig. 2.d
Ref.
11
12, 13, 14
15
16
17
18
19
10
J16
J1 7
J18
J27
J28
20
21
24
23
J29
A B
C D
J7
J6
J8
3
8
9
J22
J1 8
J1 6
J1 7
J22
J23 F Bus2
15
19
7
3
8
J20
J7
J8
8
9
Description
pLAN plug-in connector
Reserved
Relay digital outputs
BMS2 connector
FieldBus2 connector
Jumpers for selecting FieldBus/ BMS
FieldBus2 connector
Tab. 2.b
Tab. 2.c