Set these values on the device:
In the webConfig tool
In the main menu, select Configuration -> Communication -> Ethernet interface.
If the setting is made via the webConfig tool, it becomes active following transfer to the device.
A restart is not required!
Or alternatively in the display
Use the navigation buttons
the enter button
In the main menu, select the Parameter menu.
Select the Ethernet menu item.
Press the enter button to enter the menu.
Select the Ethernet interface menu item.
Press the enter button to enter the menu.
Successively select the IP address, Gateway and Net mask menu items and set the desired values.
Exit the menu with the Escape button.
The Configuration changed, system must be restarted message appears.
Confirm with OK to initiate a restart and to activate the changed configuration.
10.3.2 Automatically setting the IP address
If your system includes a DHCP server which is to be used to assign the IP addresses, proceed as follows:
In the webConfig tool
In the main menu, select Configuration -> Communication > Ethernet -> DHCP.
Or alternatively in the display
In the main menu, select the Parameter menu.
Select the Ethernet menu item.
Press the enter button to enter the menu.
Select the Ethernet interface menu item.
Press the enter button to enter the menu.
Select the DHCP activated menu item and set the desired value.
Exit the menu with the Escape button.
The Configuration changed, system must be restarted message appears.
Confirm with OK to initiate a restart and to activate the changed configuration.
The device responds to ping commands. A simple test to determine whether the address assign-
ment was successful is to enter the previously configured IP address in a ping command (e.g.
ping 192.168.60.101 in a command line window under Windows).