Online Commands For System Control - Leuze electronic BCL 608i Operating Instruction

Hide thumbs Also See for BCL 608i:
Table of Contents

Advertisement

Command
Acknowledgment
11.2

Online commands for system control

Activating sensor input
Command
Description
Parameter
Acknowledgment
Deactivating sensor input
Command
Description
Parameter
Acknowledgment
Leuze electronic
RR
If no reference codes are defined, the device responds with the RS command
and corresponding status (see command RS). For valid codes, the output cor-
responds to the following format:
RCyvxxzzzzzz
y, v, x and z are placeholders (variables) for the actual input.
y
Defined reference code no.
1
(code 1)
2
(code 2)
v
Storage location for reference code
0
RAM+EEPROM,
3
RAM only
xx
Defined code type (see command CA)
z
Defined code information (1 ... 63 characters)
+
The command activates decoding. This command is used to activate the
reading gate. It remains active until it is deactivated by one of the following cri-
teria:
• Deactivation by a manual command
• Deactivation by a switching input
• Deactivation upon reaching the specified read quality (equal scans)
• Deactivation by timeout
• Deactivation upon reaching a preset number of scans without informa-
tion.
No
None
-
The command deactivates decoding. This command can be used to deacti-
vate the reading gate. Following deactivation, the read result is output.
Because the reading gate was manually deactivated and, thus, no GoodRead
criterion was met, a NoRead is output.
No
None
BCL 608i
Online commands
61