Further Settings; 1Decoding And Processing The Read Data; 2Control Of The Decoding - Leuze electronic BCL 608i Operating Instruction

Hide thumbs Also See for BCL 608i:
Table of Contents

Advertisement

 Successively select the Activated, IP address and Port number menu items and set the desired values.
 Exit the menu with the Escape button.
10.4

Further settings

After the basic configuration of the operating mode and the communication parameters, you need to carry
out further settings.
10.4.1 Decoding and processing the read data
The device offers the following possibilities:
• Setting the number of labels to be decoded for each reading gate (0 ... 64). This is done via the Max.
no. of labels parameter.
• Definition of up to 8 different code types (4 different types if configured via the display). Labels that
match one of the defined code types are decoded. Further parameters can be set for each code
type:
• Code type (symbology)
• Number of digits: either up to 5 different numbers of digits (e.g., 10, 12, 16, 20, 24), or a range
(Interval mode) and up to three additional numbers of digits (e.g., 2 ... 10, 12, 16, 26)
• Reading reliability: the set value specifies how many times a label must be read and decoded with
the same result before the result is accepted as valid.
• Activation of the code reconstruction technology (CRT, in the webConfig tool only)
• Additional code type specific settings (in the webConfig tool only)
• Check digit method used for decoding as well as the type of check digit transmission for the output
of the read result. The two possibilities for the latter are Standard (corresponds to the standard for
the selected code type/symbology) and not Standard.
 Define at least one code type with the desired settings.
In the webConfig tool: Configuration -> Decoder
Or alternatively in the display: Parameter -> Decoder table
Data processing via the webConfig tool
In the Data and Output submenus of the Configuration main menu, the webConfig tool provides extensive
data processing options to adapt the functionality of the device to the specific reading task:
• Data filtering and segmentation in the Data submenu:
• Data filtering according to characteristics for handling identical bar code information
• Data segmentation for differentiating between identifier and content of the read data
• Data filtering according to content and/or identifier in order to suppress the output of bar codes
with specific content/identifiers
• Completeness inspection of the read data
• Sorting and formatting the output data in the Output submenu:
• Configuration of up to 3 different sorting criteria. Sorting by physical data and content of the read
bar codes.
• Formatting of the data output for the HOST.
• Formatting of the data output for the display.
10.4.2 Control of the decoding
In general, decoding is controlled via one or more of the configurable switching inputs/outputs. For this
purpose, the respective connection to the SW IN/OUT and POWER interfaces must be configured as a
switching input.
Via a switching input, you can:
• start decoding
• stop decoding
• start decoding and then stop decoding after a configurable time period
• read a reference code
• start the automatic code type configuration (AutoConfig)
Leuze electronic
Starting up the device - Configuration
BCL 608i