Determining parameter set difference to default parameters
Command
Description
Parameter
Leuze electronic
PD
This command outputs the difference between the default parameter set and
the operating parameter set or the difference between the default parameter
set and the permanent parameter set.
Comment:
The reply supplied by this command can e.g. be directly used for program-
ming a device with factory settings, whereby this device receives the same
configuration as the device on which the PD-sequence was executed.
PD<P.set1><P.set2>
<P.set1>
Parameter data set that is to be copied,
unit [dimensionless]
0
Parameter data set in permanent memory
2
Default or factory parameter set
<P.set2>
Parameter set into which the data is to be copied,
unit [dimensionless]
0
Parameter data set in permanent memory
3
Operating parameter data set in volatile memory
Permissible combinations here include:
20
Output of the parameter differences between the default and the
permanently saved parameter set
23
Output of the parameter differences between the default parame-
ter set and the operating parameter set saved in volatile memory
03
Output of the parameter differences between the permanent
parameter set and the operating parameter set saved in volatile
memory