EDITION 12/2008
OPERATING MANUAL
5.4.3
FITTING OR CHANGING ROUND JET NOZZLE
1. Switch off control unit.
2. Relieve spray gun and unit pressure!
3. Replace paint with cleaning solvent, and
4. Thoroughly fl ush spray gun.
5. Relieve spray gun and unit pressure!
6. Unscrew nozzle nut (B) by hand and remove
it.
7. Remove the nozzle body (C) and the nozzle
insert Supra (A).
8. Unscrew nozzle insert Supra (A) with the
nozzle spanner (I) from the nozzle body (C)
9. Re-assembly in reverse order.
Note:
To protect the electrode needle replace the
cap (D) when the gun is not in use.
PART NO. DOC350731
GA 2800EA, GA 2805EA
28