Configuring Basic System Information and Port Parameters
Configuring Port Parameters
N o t e
4-10
For example, the port name gi 3/2 refers to a port on the Gigabit Ethernet
interface module located in slot 3, port 2.
You can build a configuration for a module that is not yet installed. For
example, although slot 2 is empty, you can configure an interface gi 2/1 and
add an IP address to it, and then save the configuration for later use. Similarly,
a 10 gigabit interface (te 2/1) could be configured for the empty slot in the same
way.
Slot Numbering
To configure or address individual modules and ports, you must know the
corresponding slot name or number. Slot numbering is determined by the
switch model and the physical slot into which an interface module is installed .
Switch 8108fl Slot Numbering. The Switch 8108fl chassis contains 8 slots
for interface modules, 2 slots for management modules, and 2 slots for fabric
modules. The following illustration shows the numbering and naming scheme
used to identify each slot in the CLI.
FM-A FM-B
1
2
3
4
MM-A
MM-A = Primary Management Module
MM-B = Standby Management Module
FM-A = Primary Fabric Module
FM-B = Standby Fabric Module
5
7
6
8
Slots 1-8 = Interface Modules
MM-B