Output error
257
15
257
16
257
17
257
18
257
19
257
20
257
21
257
22
257
23
257
24
257
25
257
26
257
27
257
28
257
29
257
30
257
31
258
-
258
1
258
2
258
3
PSU8600power supply systems
Manual, 04.2016, A5E35883207-7-76
F
Invalid number of modules
MR
New unconfigured module detected
F
Invalid system configuration
MD
Deviating system configuration
MR
Invalid system configuration
F
Unclassified hardware fault
F
Invalid parameter
F
Unknown parameter
F
Invalid parameter.
F
Invalid parameter
MR
Module with excessive power detected
MR
Unexpected module type detected
MD
Module with reduced power detected.
F
Incompatible module detected
F
Unexpected empty slot detected
MR
Short time interruption for output 1 was
activated
MR
Buffer operation deactivated via control
contact
F
Fault at the output
F
Overload shutdown of the output
MD
Overload detected at the output
MR
Overload detected at the output
Troubleshooting
8.2 PROFINET alarm list
Invalid number of modules detected.
Invalid slot.
New unconfigured module detected.
System configuration is incorrect. Normal
operation of the system is not possible.
System configuration is different. Devia-
tions from the expected response may
occur outside normal operation.
System configuration is different. The
system can be operated.
Unclassified hardware fault has occurred.
All outputs of the power supply system
have been switched off.
Faulty parameter detected.
Unknown parameter detected.
Invalid parameter value transferred.
Invalid parameter
A module with excessive power was
detected. Normal system operation is
possible.
Unexpected module type detected.
A module with reduced performance was
detected. A different system response is
possible.
The module type is incompatible to the
configuration. The module cannot be
commissioned.
Unexpected empty slot detected.
The short time interruption function for
output 1 was activated. As soon as buffer
operation of the supply voltage returns,
the voltage at output 1 is interrupted for
the defined duration. However, the short
time interruption is realized at the earliest
after the defined wait time expires.
The buffer readiness of all of the buffer
components in the system were deac-
tivated by an external hardware control
contact.
Fault at the output
Inadmissible overload at the output has
occurred. The output was shut down.
Output current at the output is still within
the permissible overload profile based on
specified response threshold.
Output current is above the specified
warning threshold. Operation can contin-
ue without restrictions.