CVA 265x & CVA 266x
Number of Pulses
About 15
<2 (for more than 7 seconds)
0 (for more than 7 seconds)
Table 060-11: Flow Meter Pulse Rates
Page 1
Page 2
Table 060-12: Sensor/Switch Check Reference
4.5.2
CVA 2652/2662
Initial requirements:
Switch off the machine.
Accessing:
Note:
The service mode must be accessed within 2 seconds.
1. Press and hold the Cup Size touchpad.
2. Press the On/Off touchpad once.
3. Release the Cup Size touchpad.
4. Press and release the On/Off touchpad 3 times; on the 3rd time, hold it
pressed in until the service mode is accessed.
Acknowledgement indicator:
The display shows Service mode in the upper left-hand corner.
Options:
Press the < or > touchpads until the desired service function is displayed;
see Table 060-13.
Press the OK touchpad.
Press the < or > touchpads until the desired option is displayed; see
Table 060-13.
Quit: Press the On/Off touchpad to switch off the appliance.
Display
Door contact switch
Water container sensor
Steam valve sensor
Drip tray present
Drip tray full
Waste container present
87
Technical Information
Explanation
Water intake in order (w/o capsule)
Insufficient water intake (F17: Section 060-3.8)
No water intake (F10: Section 060-3.7)
Explanation
0 = Door open
1 = Door closed
0 = Water container empty/not installed
1 = Water container filled/installed
0 = Steam valve closed
1 = Steam valve open
0 = Drip tray not installed
1 = Drip tray installed
0 = Drip tray not full
1 = Drip tray full (needs to be emptied)
0 = Waste container full or not installed
1 = Waste container OK and installed