Please Empty Drip Tray" Is Displayed (Drip Tray Not Full); Figure 060-6: Base Plate Removal; Figure 060-7: Contact Springs In Housing - Miele CVA 2650 Technical Information

Hide thumbs Also See for CVA 2650:
Table of Contents

Advertisement

CVA 265x & CVA 266x

Figure 060-6: Base Plate Removal

5. Check the connections to the springs and correct them if necessary; see
Figure 060-7.

Figure 060-7: Contact Springs in Housing

3.25

"Please Empty Drip Tray" is Displayed (Drip Tray Not Full)

Cause:
Contacts dirty, corroded, or coated with film (e.g., dishwasher rinse aid).
Remedy:
Clean and dry the contacts.
Cause:
The base plate has filled with water or leakage in water system.
Remedy:
Empty the base plate.
Carefully inspect the hoses and ensure that the water connections and
components do not leak.
75
Technical Information
1 Contact springs – "Drip tray present" sensor
connections: Red or orange
2 Contact spring - Drip tray level sensor
connection: Brown