Brew Unit Motor Removal; Figure 050-3: Brew Unit And Retaining Screws - Miele CVA 2650 Technical Information

Hide thumbs Also See for CVA 2650:
Table of Contents

Advertisement

CVA 265x & CVA 266x
Technical Information
8. Disconnect the electrical connections from the brew unit.
9. Remove the brew unit.

Figure 050-3: Brew Unit and Retaining Screws

4.2

Brew Unit Motor Removal

1. Remove the appliance for service; see Section 010-4.1.
2. Remove the left and right side panels.
3. Remove the rear panel.
4. Remove the top casing (Section 010-4.5).
5. Remove the retaining clip (Figure 050-4, Item 1).
6. Pull off the encoder (Figure 050-4, Item 2).
7. Remove the brew unit motor retaining screws (Figure 050-4, Item 3).
8. Remove the brew unit motor.