Display Position
Value (Approx.)
046
012
167
150
010
172

Table 060-14: Brew Unit Position Sensor (B10) Display Codes

Number of Pulses
About 15
<2 (for more than 7 seconds)
0 (for more than 7 seconds)

Table 060-15: Flow Meter Pulse Rates

4.6

Pressure Test

Required tools:

Figure 060-8: Pressure-Measuring Instrument Set

Note:
A small measuring container will also be required for this test.
1. Let the appliance warm up to normal operating temperature.
2. Remove the capsule magazine from the appliance.
3. Remove the capsule plate (Figure 060-9, Item A).
4. Remove the rubber insert (Figure 060-9, Item B).
Position Explanation
Rest
Eject
Press (with capsule plate only)
Service
Raised end position
Lower end position (with capsule plate only)
Explanation
Water intake in order (w/o capsule)
Insufficient water intake (F17: Section 060-3.8)
No water intake (F10: Section 060-3.7)
1 Connection piece
2 Holding bracket
3 Pressure-measuring instrument
90
CVA 265x & CVA 266x