Decompression Vessel Removal - Miele CVA 2650 Technical Information

Hide thumbs Also See for CVA 2650:
Table of Contents

Advertisement

CVA 265x & CVA 266x
Technical Information
3. Remove the rear panel.
4. Remove the top casing (Section 010-4.5).
5. Remove the carrier panel (Section 040-4.2).
6. Disconnect the hoses from the flow meter (Figure 030-4, Item 6).
7. Lift the flow meter up and off its support to remove.
8. Disconnect the electrical connections from the flow meter.
4.8

Decompression Vessel Removal

1. Remove the appliance for service; see Section 010-4.1.
2. Remove the left and right side panels.
3. Remove the rear panel.
4. Remove the top casing (Section 010-4.5).
5. Remove the carrier panel (Section 040-4.2).
6. Remove the three T10 screws securing the vessel to the carrier panel;
see Figure 030-4, Item 5.
7. Note the hose positions, and then disconnect the hoses from the vessel.
8. Remove the vessel.