Miele CVA 2650 Technical Information page 88

Hide thumbs Also See for CVA 2650:
Table of Contents

Advertisement

Technical Information
Function
ID number
Fault memory
Component test
Option/Component Activated
EPWZ
EPL
Fault codes are listed, one at a time.
Delete
1
M26 (Brew unit)
1
M29 (Ceramic valve)
M30 (Capsule transport
1
motor)
M31 (Capsule
1
magazine motor)
1M7 (Steam pump)
88
CVA 265x & CVA 266x
Initialize
Rest position
Eject position
Press position
Service position
Continuous upwards
Continuous downwards
Initialize
Step counterclockwise
Step clockwise
Rest position
Coffee position
Water position
Continuous
counterclockwise
Continuous clockwise
Initialize
Carry out
Service position
Continuous operation
Initialize
Step counterclockwise
Step clockwise
Chamber 1 to 5
Continuous
counterclockwise
Continuous clockwise
Release
Cappuccinatore
Continuous operation
Description
ID no. and version of EPWZ
855 control/display electronic
ID no. and version of EPL 855
power electronic
See Table 060-2 for fault code
descriptions.
Press OK to clear the fault
memory.
To reach the lowered end
position, the capsule plate must
be removed from the brew unit
beforehand.
The press position can only be
reached with the capsule plate
installed.
(See also Table 060-14.)
The position of the step contact
switch (S51/1) is indicated in
the top right corner of the
display. 0 = Switch open;
1 = Switch closed.
The position of the step contact
feed switch (S51/3) is indicated
in the top right corner of the
display. 0 = Switch open;
1 = Switch closed.
The position of the capsule
magazine step contact
switch (S51/2) is indicated in
the top right of the display.
0 = Switch open;
1 = Switch closed.
The pump passes residual
water/steam along the water
path, see Section 030-2.1.
The pump passes steam along
the water path, see Section
030-2.1.
The pump is activated
constantly.