Capsule Cage Replacement; Table 060-5: Customer Programming, Cva 2652/2662; Table 060-6: Water Hardness Settings - Miele CVA 2650 Technical Information

Hide thumbs Also See for CVA 2650:
Table of Contents

Advertisement

Technical Information
Option
Maintenance
Showroom
prog.
Factory default

Table 060-5: Customer Programming, CVA 2652/2662

1
If the language is set incorrectly, search for the flag symbol
setting area.
Water Hardness
Setting
1 - Soft
2 - Medium
3 - Hard
4 - Very Hard

Table 060-6: Water Hardness Settings

4.2

Capsule Cage Replacement

After approximately 15,000 coffees have been served, the capsule cage in
the brew unit must be replaced (see the operating instructions).
1. Access the programming mode as outlined in Section 060-4.1.1 or 060-4.1.2.
2. Turn the right switch knob or press the < or > touchpads until
MAINTENANCE is displayed.
3. Press the right switch knob or the OK touchpad.
4. Turn the right switch knob or press the < or > touchpads until Carry out is
displayed.
5. Press the right switch knob or the OK touchpad to carry out the service task.
6. The brew unit transports the capsule cage downwards.
7. Open the door.
8. Remove the capsule plate.
9. Remove the seal downwards.
10. Unscrew the capsule cage using the service tool.
11. Install a new capsule cage using the service tool.
12. Install the seal from underneath.
13. Slide in the capsule plate.
14. Close the door. The brew unit will move the capsule cage upwards. The
appliance can be operated again normally.
Setting
Carry out
Demo program
Off
All settings
User profiles
Water Hardness
Grains per
Gallon
0 to 7
8 to 14
15 to 21
> 21
82
CVA 265x & CVA 266x
Description
Perform capsule cage
replacement; see
Section 060-4.2.
The appliance can be
operated but does not
heat up.
The demo program is
deactivated.
All settings adjusted
within programming
mode will be reset
(the language setting
remains unchanged).
The demo program, if
set, remains
activated.
All user profiles are
deleted.
to enter the language
Max. Flow Quantities until
Descale is Displayed
Parts per
Steam
Million
0 to 125
92 oz.
143 to 250
69 oz.
268 to 375
46 oz.
>375
23 oz.
Standard Setting
-
Off
-
Coffee/Hot
Water
4058 oz.
3043 oz.
2029 oz.
1353 oz.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cva 2652Cva 2660Cva 2662

Table of Contents