Table 060-8: Service Functions, Cva 2650/2660; Table 060-9: Capsule Magazine Check; Table 060-10: Brew Unit Display Codes - Miele CVA 2650 Technical Information

Hide thumbs Also See for CVA 2650:
Table of Contents

Advertisement

Technical Information
Function
Component test
Sensor/switch
test
Operating hours
Calibration

Table 060-8: Service Functions, CVA 2650/2660

1
To save the fault memory, press and hold the left switch knob until the service mode is
deactivated. The fault memory is not deleted. To clear the fault memory, turn the right
switch knob until Back is displayed, and then press the right control knob.
2
To reset to the basic setting and to avoid mechanical damage, always advance to the
Initialize setting as a final step.
3
To ensure that the flow-through heater does not become too hot, causing the fuse to
melt, only press the right switch knob briefly to check whether the heater is activated.
Display
Capsule magazine sensor
Magazine position sensor
Magazine drawer sensor

Table 060-9: Capsule Magazine Check

Display Position
Value (Approx.)
046
012
169
150
009
185

Table 060-10: Brew Unit Display Codes

Option/Component Activated
3
Heater - water
3
Heater - steam
Page 1
Page 2
Operating hours
Number of uses
Number of descale procedures performed
Cancel descaling
Mains frequency
Explanation
0 = Chamber empty
1 = Chamber full
0 = Capsule magazine state
before and after the stop pulse
1 = Brief stop pulse for capsule
magazine motor
0 = Capsule magazine drawer
not inserted
1 = Capsule magazine drawer
inserted
Position Explanation
Rest
Eject
Press (with capsule plate only)
Service
Raised end position
Lower end position (with capsule plate only)
86
CVA 265x & CVA 266x
Door contact
Water container
Steam spout
Drip tray present
Drip tray full
Waste container
Coffee/hot-water heater
Steam heater
Coffee
Hot water
Steam
Yes/No
50Hz
60Hz (all US models)
Notes
Only active when the
capsule magazine
motor is activated
--
--
Description
The display shows the
temperature registered by the
NTC sensor on the selected
heater.
Sensor/switch test
(Table 060-12)
Operating hours displayed
Number of servings
Number of times descale
procedure was performed
Resets descale timer
Sets mains (line) frequency

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cva 2652Cva 2660Cva 2662

Table of Contents