Figure 060-4: Modified Capsule Transport Arm With 55° Bezel (2650/2660) - Miele CVA 2650 Technical Information

Hide thumbs Also See for CVA 2650:
Table of Contents

Advertisement

CVA 265x & CVA 266x
Cause:
The groove in which the slide moves (Figure 060-3, Item 3) is soiled with coffee
residue (e.g., after a capsule has exploded) and the slide (Figure 060-3, Item 2)
is stuck. The capsule transport arm (Figure 060-3, Item 1) can also get stuck.
Series modification (CVA 2650/2660 only):
Since machine no. 16/65408179, a different power electronic with modified
rinse method has been used.
Since machine no. 60/65417375, the capsule transport arm has been
shortened by 0.07 inches (1.7 millimeters) and fitted with a 55° bezel (see
Figure 060-4).
The capsule plate and capsule magazine slide have been improved.
Figure 060-4: Modified Capsule Transport Arm with 55° Bezel (2650/2660)
Quantity
1
1
1
1
1
Remedy:
1. Thoroughly clean the groove (Figure 060-3, Item 3) and the slide (Figure
060-3, Item 2).
Warning!
Do not apply grease to the groove or the slide!
Using grease will eventually create a large buildup of oil and dirt which will
cause the transport mechanism to jam.
2. Lubricate the capsule transport arm with HTS 600 grease, as shown in
Figure 060-5, Item 1.
Mat. No.
Description
06216475
Power electronic with modified rinse method
06059013
Capsule transport arm (includes installation
instructions, mat. no. 06959000)
06109450
HTS 600 grease
07198560
Capsule plate (receptacle)
06264371
Capsule magazine slide
69