Technical Information
1
Technical Data
Coffee/Hot-Water Heater (2R1)
Version
Voltage
Power rating
Up to index 13/...: 2 fuses (2F8, 3F8)
After index 14/...: 1 fuse (2F8)
1 temperature limiter (2F1 or F1/8)
NTC temperature sensor (2R30)
77°F (25°C)
212°F (100°C)
320°F (160°C)
Steam Heater (1R1)
Version
Voltage
Power rating
Fuse (1F8)
Temperature limiter (1F1 or F1/5)
NTC temperature sensor (1R30)
77°F (25°C)
212°F (100°C)
320°F (160°C)
Table 030-1: Heater Data
Coffee/Hot-Water Pump (2M7)
Motor type
Voltage
Watts
Temperature limiter (4F1 or 2F3)
Steam Pump (1M7)
Motor type
Voltage
Watts
Temperature limiter (3F1 or 1F3)
Table 030-2: Pump Data
Flow Meter (B3/4)
No. of pulses
Table 030-3: Flow Meter Data
With stainless-steel water pipe
120VAC
1200W
421°F, 363°F (216°C, 184°C)
421°F (216°C)
241°F (116°C)
100kΩ
5.5kΩ
1kΩ
With stainless-steel water pipe
120VAC
1200 W
421°F (216°C)
347°F (175°C)
100kΩ
5.5kΩ
1kΩ
Piston pump
120VAC
60W
239°F (115°C)
Piston pump
120VAC
65W
239°F (115°C)
2 pulses/revolution
36
CVA 265x & CVA 266x