Service Mode Summary; Table 060-7: Service Programming, Cva 2652/2662 - Miele CVA 2650 Technical Information

Hide thumbs Also See for CVA 2650:
Table of Contents

Advertisement

Technical Information
Option
Reset
Service

Table 060-7: Service Programming, CVA 2652/2662

4.5

Service Mode Summary

4.5.1
CVA 2650/2660
Initial requirements:
Switch off the machine.
Accessing:
Note:
The service mode must be accessed within 2 seconds.
1. Press and hold the right switch knob.
2. Press the left switch knob once. The appliance is switched on.
3. Release the right switch knob.
4. Press and release the right switch knob 3 times; on the 3rd time, hold it
pressed in until the service mode is accessed.
Acknowledgement indicator:
The left display shows SERVICE MODE.
The right display shows PROGRAM INDEX.
Options:
Turn the right switch knob until the desired service function is displayed;
see Table 060-8.
Press the right switch knob.
Turn the right switch knob until the desired option is displayed; see Table 060-8.
Back: Turn the right switch knob until Back is displayed. Press the right
switch knob.
Save and quit: Press and hold the left switch knob until the service mode
is deactivated.
Setting
Press OK to reset all settings
(except language) to their
standard values.
Descale
Reset
50Hz
Frequency
60Hz
Espresso
Coffee
Temperature
Hot water
84
CVA 265x & CVA 266x
Description
Standard Setting
All standard settings
(except language) are
-
reset.
Descaling timer will
be reset. Always
descale the
-
appliance after
completing service
work.
Set the mains (line)
60Hz
frequency.
Set the temperature
(minimum to
Medium
maximum) for each
drink type.