F3 Group - Start And Stop Control Group - Powtran PI9000-S Series User Manual

Frequency inverter
Table of Contents

Advertisement

pulse
SPB terminal is selected as pulse output, the function code is used to select the maximum
value of output pulse.
SPB switching quantity
F2.10
output delay time
F2.11
Relay 1 output delay time 0.0s to 3600.0s
F2.13
SPA output delay time
F2.14
Relay 2 output delay time 0.0s to 3600.0s
Set the delay time from occurrence to Actual output for output terminal SPA, SPB,
relay 1, relay 2 and expansion DO.
DO output terminal
F2.15
active status selection
To define the output logic for output terminal SPA, SPB, relay 1, relay 2 and
expansion DO .0: positive logic:It is active status when the digital output terminal is
connected with the corresponding common terminal, inactive when disconnected; 1: anti-
logic:It is inactive status when the digital output terminal is connected with the
corresponding common terminal, active when disconnected;

5-1-5.F3 Group - Start and stop control group

Code
Parameter name
F3.00
Start-up mode
F3.03
Start frequency
Hold time for start
F3.04
frequency
0.0s to 3600.0s
0.0s to 3600.0s
SPB switching quantity
Units
active status selection
digit
Positive logic
Anti-logic
Relay 1 terminal active
Tens
status setting (0 to 1, as
digit
above)
Expansion
Hund
active status setting (0 to 1,
reds
as above)
digit
Thou
SPA terminal active status
sands
setting (0 to 1, as above)
digit
Ten
Relay 2 terminal active
thous
status setting (0 to 1, as
ands
above)
digit
Setting range
Direct startup
Speed tracking restart
Pre-excitation
start
asynchronous motor)
0.00Hz to 10.00Hz
0.0s to 100.0s
37
Chapter5.Function parameter
0
1
D0
terminal
00000 ☆
Factory
range
0
1
0
(AC
2
0.00Hz
0.0s
0.0s
0.0s
0.0s
0.0s
Chan
ge
Limit

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents