Basic Function Group: F00-F50 (0X0000-0X0032) - Powtran PI8600 Series User Manual

Powtran pi8600 family frequency inverter
Table of Contents

Advertisement

S06
Motor real speed
Under running, the real speed of the motor=60*the real output frequency *Gain Speed
surveillance /pole of the motor .
Example: the real output frequency50.00Hz, Gain Speed surveillance A35=100.0%, the pole
of the motor b03/b16=2, the real speed of the motor=1500rpm.
When stop, based Residual voltage test motor speed, renew speed 500ms.
The real speed =60*residual frequency*Gain Speed surveillance / the pole of the motor
Max display of motor real speed 9999rpm.
S07
Total running time
When the ouptput, the frequency inverter calculated the running time.
Total running time can be cleared up automatically with A33 selecting reboot or continue
accumulation after reboot
Total running time of the units can be changed by parameter A34, you can choose hours or
days as the unit
S08
IGBT temperature℃
S09
PID set point
S10
PID feedback
S11
Motor output frequency
The output frequency of the motor=the actual frequency of the motor *A36the regulate of
the motor frequency
Max display of the output frequency 2999.9
S12
Excitation heft set value
Excitation heft actual
S13
value
S14
Torque heft Set value
S15
Torque heft actual value
5-3 Basic Function Group:F00-F50(0x0000-0x0032)
Code
Description / LCD
F00
Control mode
Control mode choose, setting 0~2.
0 : V/ Fcontrol
It is not sensitive to motor parameters, can be used as power supply; for motor control, using
the combination of vector control and V / F control strategies, appropriately adjusts motor
Section V Parameter Function Table
Motor real running speed
The total running time for every
time
Test the temperature of IGBT in
the frequency
PID Adjust run-time values of the
percentage of a given
PID Adjust run-time values of the
percentage of feed back
The percentage of actual output
power of motor
Motor set excitation heft percentage
Motor actual excitation heft
percentage
Motor set torque percentage
Motor actual torque heft percentage
Setting Range
V/Fcontrol
Sensorless vector control
Sensor feedback close loop