Error Log Reference
T
Chapter
1
(1) (2)
(3)
W
PD A600
W
PD A601
W
PD A700
Chapter
2
W
PD A701
W
PD A702
W
PD A703
W
PD A704
W
PD A705
W
PD A800
Chapter
W
PD A801
3
W
PD A802
W
PD A803
W
PD A900
W
PM 2300
Chapter
4
W
PM 7E01
W
PM 7E02
W
PM B800
W
PM C100
W
PM C200
W
PM C300
W
PN 2600
Chapter
5
W
PN 2610
W
PN 2620
W
PN 2630
W
PN 2640
W
RM 2B01
W
SC
2300
W
SN 6000
W
SN C000
W
SN C010
W
SN C020
W
SP
A000
(1) Type (2) Character string (3) Error number
206
LP-1030/LP-1030-MF User's Manual for Basic Printer Operation
Message
RASTER_DECODE_ERR
An error exists in the format of the compression
raster data.
RASTER_FORMAT_ERR
No raster data of the size specified in the data.
PDL ERR 700
A controller internal format error occurred.
PDL ERR 701
PDL ERR 702
PDL ERR 703
PDL ERR 704
PDL ERR 705
FORMATERROR
An error exists in the TIFF data. Alternatively,
cannot print because a required tag is missing.
# OF PARAM. ERROR
The number of parameters for the TIFF data tags
is incorrect.
PARAM._RANGE_ERR
The parameter value for the TIFF data tags is
outside the supported range.
DATA IGNORED
Data was disregarded because there was no
valid print data in the TIFF data.
FORMATERROR
Cannot print because the required CALS format
record is missing.
HDD format execution
Factory default setting execution
Printer initialization execution
Login unauthenticated
Internal communication parameter error
Statuses do not match
Internal process parameter error
Panel unit not connected
Occurs when a response cannot be received for
the panel initialization command.
(Occurs in a panel task)
Undefined command received
Occurs when an undefined command is received
from the panel unit.
(Occurs in a panel task)
Cmd Retry
Command resent because there was no
response for the command from the panel for a
certain time.
(Occurs in a panel driver)
Cmd Timeout
Disposed of the command because the
command from the panel was interrupted
partway.
(Occurs in a panel driver)
Pipe Overflow
Disposed of the command from the panel
because of an upper pipe overflow.
(Occurs in a panel driver)
Resource open error
Resource file opening error
Image Over Run
Image disk writing too late
Setup access error
MIB information construction error
MIB information access error
Internal communication error
Cannot Parse PJL
PJL analysis failed
* Details may be divided into multiple items
Meaning
Check on the computer side
for an error in the format of the
compression raster data.
Check on the computer side for an
error in the data.
When the error persists and there is
a problem in the printout, upgrade
the system.
Correct the error on the computer
side.
Check on the computer side whether
valid print data is being transmitted.
Correct the error on the computer
side.
Restart the Printer, and when the
error persists, upgrade the system.
Restart the Printer.
-
Restart the Printer.
Restart the Printer, and when the
error persists, upgrade the system.
-
-
-
-
Check the print data.
Action