Omron Programmable Terminals NT31 NT31C Setup Manual page 66

Programmable terminals
Table of Contents

Advertisement

Connecting to the RS-232C Port at the Host
PC Se-
Units with Built-in Host Link
ries
Function
CS1 Se-
CS1G-CPU42/43/44/45-EV1
ries
CS1H-CPU63/64/65/66/67-EV1
---
---
C200HS-CPU21/23/31/33-E
C200HE-CPU42-E
C20HE-CPU42-ZE
C200HG-CPU43/63-E
C200HG-CPU43/63-ZE
C200HX-CPU44/64-E
C200HX-CPU44/64/65/85-ZE
C Series
---
---
CPM1-10/20/30CDR-j
CPM1A-10/20/30/40CDj
CPM2A-30/40/60CDjj
(Peripheral port connection)
CPM2C-10/20jjjjjj
CQM1-CPU21-E
CQM1-CPU41/42/43/44-EV1
CQM1H-CPU11/21/51/61 (*2)
CV500-CPU01-EV1
CV Se-
CV Se
CV1000-CPU01-EV1
ries (*3)
ries (*3)
CV2000-CPU01-EV1
CVM1
CVM1-CPU01-EV2
Series
CVM1-CPU11-EV2
(*3)
CVM1-CPU21-EV2
Compo-
Bus/S
SRM1-C02-V1
master
control
unit
*1: Use a CPM2C-CN111 or CS1W-CN114/118 Connecting Cable, CPM1-CIF01 RS-232C Adapter, or CPM1-CIF11
RS-422A Adapter to connect.
*2: The CQM1H-CPU11 does not have a built-in RS-232C port, so connect to the peripheral port to the PT with a
CS1W-CN118 Connecting Cable.
*3: CPUs of CVM1/CV-series PCs without the suffix -EVj cannot be connected.
The host units that can be connected to the NT31/NT31C by the host link method
using the RS-232C ports of both units are indicated in the table below.
CPUs Connectable with Host Link
Units or Expansion Communication
CS1G-CPU42/43/44/45-EV1
CS1H-CPU63/64/65/66/67-EV1
C1000H-CPU01-EV1
C2000H-CPU01-EV1
C200HS-CPU01/03/21/23/31/33-E
C200HE-CPU11/32/42-E
C200HE-CPU11/32/42-ZE
C200HG-CPU33/43/53/63-E
C200HG-CPU33/43/53/63-ZE
C200HX-CPU34/44/54/64-E
C200HX-CPU34/44/54/64/65/85-ZE
---
C200HE-CPU32/42-E
C200HE-CPU32/42-ZE
C200HG-CPU33/43/53/63-E
C200HG-CPU33/43/53/63-ZE
C200HX-CPU34/44/54/64-E
C200HX-CPU34/44/54/64/65/85-ZE
C1000H-CPU01-EV1
C2000H-CPU01-EV1
C1000H-CPU01-EV1
C1000HF-CPU01-EV1
C2000H-CPU01-EV1
---
+CPM1-CIF01
-
j
---
+CPM1-CIF01
j
-
---
+CPM1-CIF01
j
-
---
(*1)
---
CQM1H-CPU51/61
CV500-CPU01-EV1
CV1000-CPU01-EV1
CV2000-CPU01-EV1
CVM1-CPU01-EV2
CVM1-CPU11-EV2
CVM1-CPU21-EV2
---
Communication Board
Board
CS1W-SCU21
CS1W-SCB21
CS1W-SCB41
C120-LK201-EV1
C200H-LK201-EV1
---
C200HW-COM02/04/
C500-LK201-EV1
C500-LK203
---
---
---
---
---
CQM1H-SCB41
CV500 LK201
CV500-LK201
CV500-LK201
---
Section
Host Link Unit/
Connectable
CS1G
CS1H
C1000H
C2000H
C200HS
C200HE
C200HE-Z
C200HG
C200HG-Z
C200HX
C200HX-Z
C200HS
C200HE
C200HE-Z
C200HG
C200HG-Z
05/06-EV1
05/06 EV1
C200HX
C200HX-Z
C1000H
C2000H
C1000H (F)
C2000H
CPM1
CPM1
CPM2A
CPM2C
CQM1
CQM1H
CV500
CV1000
CV2000
CVM1
SRM1
4-1
to
55

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Programmable Terminals NT31 NT31C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Nt31Nt31c

Table of Contents