Making the Cable
5. Wrap vinyl tape over the cut off end of the shielding wire.
Soldering
1, 2, 3...
1. Slide heat-shrink tube over each wire.
2. Pre-solder each wire and connector terminal.
3. Solder each wire to each connector terminal.
4. Push the heat shrink tube over the soldered joint and heat the tube to shrink it in place.
Hood Assembly
Assemble the connector hood as shown below.
268
(1)
(2)
40 (1.57) (RS-232C)
25 (0.98) (RS-422A)
(3)
(4)
5
(0.19)
(5)
Units: mm (inch)
1 mm
Heat-shrink tube
(F, 1.5 mm dia.,
= 10 mm)
Aluminum foil tape
End connected to FG
Appendix E
Vinyl tape
Soldering iron
Heat-shrink tube
End not connected to FG