Parameter List - Mitsubishi Electric FR-F500 Series Instruction Manual

Transistorized inverter
Hide thumbs Also See for FR-F500 Series:
Table of Contents

Advertisement

4.1 Parameter List

4 PARAMETERS
4.1 Parameter List
4.1.1 Parameter list
All parameters available when the Pr. 160 "user group read selection" value is "0" are indicated below.
The parameters available when the Pr. 160 value is "9999" (Simple mode parameter) are marked in the
Parameter Number column with a circle ($).
Func-
Parameter
tion
Number
$
0
Torque boost
$
1
Maximum frequency
$
2
Minimum frequency
$
3
Base frequency
$
4
Multi-speed setting (high speed)
$
5
Multi-speed setting (middle speed)
$
6
Multi-speed setting (low speed)
$
7
Acceleration time
$
8
Deceleration time
$
9
Electronic thermal O/L relay
$
10
DC injection brake operation frequency
$
11
DC injection brake operation time
$
12
DC injection brake voltage
$
13
Starting frequency
$
14
Load pattern selection
15
Jog frequency
16
Jog acceleration/deceleration time
17
MRS input selection
$
19
Base frequency voltage
Acceleration/deceleration reference
20
frequency
Acceleration/deceleration time
21
increments
22
Stall prevention operation level
Stall prevention operation level
23
compensation factor at double speed
24
Multi-speed setting (speed 4)
25
Multi-speed setting (speed 5)
26
Multi-speed setting (speed 6)
27
Multi-speed setting (speed 7)
28
Multi-speed input compensation
29
Acceleration/deceleration pattern
30
Regenerative function selection
31
Frequency jump 1A
32
Frequency jump 1B
33
Frequency jump 2A
34
Frequency jump 2B
35
Frequency jump 3A
36
Frequency jump 3B
37
Speed display
38
Automatic torque boost
Automatic torque boost operation
39
starting current
Name
Setting Range
0 to 3600 s/
0 to 3600 s/
0 to 120Hz, 9999
0 to 10 s, 8888
0 to 3600 s/
0 to 1000V, 8888, 9999
0 to 150%, 9999
0 to 200%, 9999
0 to 120Hz, 9999
0 to 120Hz, 9999
0 to 120Hz, 9999
0 to 120Hz, 9999
0 to 120Hz, 9999
0 to 120Hz, 9999
0 to 120Hz, 9999
0 to 120Hz, 9999
0 to 120Hz, 9999
0 to 120Hz, 9999
62
Minimum
Setting
Increments
0 to 30%
0.1%
0 to 120Hz
0.01Hz
0 to 120Hz
0.01Hz
0 to 120Hz
0.01Hz
0 to 120Hz
0.01Hz
0 to 120Hz
0.01Hz
0 to 120Hz
0.01Hz
0.1 s/
0 to 360 s
0.01 s
0.1 s/
0 to 360 s
0.01 s
0 to 500A
0.01A
0.01Hz
0.1 s
0 to 30%
0.1%
0 to 60Hz
0.01Hz
0, 1
1
0 to 120Hz
0.01Hz
0.1 s/
0 to 360 s
0.01 s
0,2
1
0.1V
1 to 120Hz
0.01Hz
0,1
1
0.1%
0.1%
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0, 1
1
0, 1, 2, 3
1
0, 2
1
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0,1 to 9998
1
0 to 200
0.1%
0 to 500
0.01A
PARAMETERS
Factory
Cust-
Refer
Setting
omer
To
〈 〈 〈 〈 EC
Set-
Page:
Version〉 〉 〉 〉
ting
6%/4%/3%
/2%
68
(Note 4)
120Hz
69
0Hz
69
60Hz
70
〈50Hz〉
60Hz
71
30Hz
71
10Hz
71
5 s/15 s
72
(Note 1)
10 s/30 s
72
(Note 1)
Rated
output
73
current
3Hz
74
0.5 s
74
4%/2%
74
(Note 1)
0.5Hz
75
1
76
5Hz
77
0.5 s
77
0
78
9999
70
〈8888〉
60Hz
72
〈50Hz〉
0
72
120%
79
9999
79
9999
71
9999
71
9999
71
9999
71
0
80
0
81
0
82
9999
83
9999
83
9999
83
9999
83
9999
83
9999
83
0
84
0
85
0
85

Advertisement

Table of Contents
loading

Table of Contents