7.1 Option List

7 OPTIONS
7.1 Option List

7.1.1 Stand-alone options

Name
Parameter unit
FR-PU04
(8 languages)
Parameter unit
FR-CB2""
connection cable
Heatsink outside
FR-A5CN""
attachment
Totally enclosed
structure
FR-A5CV""
attachment
Attachment for
FR-A5FN""
conduit connection
FR-A100E series
installation
FR-A5AT""
interchange
attachment
EMC Directive
compatible noise
SF""
filer (Note 3)
Surge voltage
FR-ASF-H""
suppressing filter
Power factor
FR-BEL-(H)""
improving DC
(Note 1)
reactor
Power factor
FR-BAL-(H)""
improving AC
(Note 1)
reactor
FR-BIF-(H)""
Radio noise filter
(Note 1)
FR-BSF01
Line noise filter
FR-BLF
BU-1500 to 15K,
BU brake unit
H7.5K to H30K
FR-BU-15K to
Brake unit
55K, H15K to
H55K
FR-BR-15K to
Resistor unit
55K, H15K to
H55K
FR-RC-15K to
Power regeneration
55K, H15K to
converter
H55K
FR-CV 7.5K to
30K(-AT), 37K,
Power regeneration
55K, H7.5K to
common converter
H30K(-AT), H37K,
H55K (Note 5)
FR-HC7.5K to
High power factor
55K, H7.5K to
converter
H55K
Type
Interactive parameter unit using LCD display (For use in
Japanese, English, German, French, Spanish, Italian,
Swedish and Finnish)
Cable for connection of the operation panel or parameter
unit.
Used to place only the heat generating section of the
inverter in the back of the control box.
By installing this option, the inverter meets the totally
enclosed structure specifications (IP40).
Used to connect a conduit directly.
Mounting plate used to make the mounting dimensions
identical to those of the FR-A100E series models.
Noise filer conforming to the EMC Directive (EN50081-2)
Suppresses surge voltages on the inverter output side.
Used to improve the inverter input power factor (overall
power factor about 95%) and cooperate with the power
supply.
Used to improve the inverter input power factor (overall
power factor about 90%) and cooperate with the power
supply.
For radio noise reduction
For line noise reduction (applies to small capacities of
3.7kW or less)
For line noise reduction
Used to improve the braking capability of the inverter (for
high-inertia load or negative load).
Used to improve the braking capability of the inverter (for
high-inertia load or negative load). Use the brake unit and
resistor unit together.
High-function brake unit which can return motor-generated
braking energy to the power supply.
High-function unit which can return motor-generated
braking energy back to the power supply in common
converter system.
The high power factor converter switches the converter
circuit on-off to convert the input current waveform into a
sine wave to suppress harmonics considerably. (Used with
the standard accessories.)
Application, Specifications, etc.
195
OPTIONS
Applicable
Inverter
Common to
all models
1.5K to
55K,
according
to capacity
0.75K to
22K,
according
to capacity
30K to
55K,
according
to capacity
0.75K to
55K,
according
to capacity
0.75K to
55K,
according
to capacity
0.75K to
55K,
according
to capacity
0.75K to
55K,
according
to capacity
0.75K to
55K,
according
to capacity
Common to
all models
According
to capacity