Technical Product Manual - DCT1900
Installation Instructions, Base Station – KRC 101 1371
Locate Small
Pattern
Mounting
Plate where
shown and
drill .375 dia.
mounting
holes
3.0"
2.50 X .312 slot, 2 places
(both ends, one side of tube only)
0.975
SCALE: 1:1
NOTES:
1.
Material: 1.00" Schedule 40 6061-T6 aluminum tubing (O.D. = 1.315", Wall = 0.133")
2.
Finish: clear anodize type II
3.
Dimensions: X.XX = +/- .030", X.XXX = +/- .010"
16-16
Weatherproof
Housing (rear view)
5.0"
Fig. 16-14 Mounting Plate Attachment to Housing
.156r
Dimension A
(see table)
Fig. 16-15 Mounting Arm
3/8"
3/8"
Hex Nut
Flat
Washer
3/8"
Bolt
.312 dia
4 places
Dimension A Length
Part Number
1301-SXA 120 8411/1
1301-SXA 120 8411/2
1302-SXA 120 8411/3
0.975
6.00"
12.00"
18.00"
Install-DCT1900/R8/mw