6
HAPTER

Relation between Parts

Radio Exchange
Item
Modular Cabinet
CPU
SLU
DTU-E1, CCS
DTU-T1, CCS
DTU-E1, CAS
DTU-T1, CAS
LTU
DLU
CLU
CLU-S
SPU
MCCB
SDB
Config-DCT1900/R8/mw
© 2000-2005
Connects
9 System Boards
1 Connection Board
2 Power Supplies
PC, Printer, General Alarm, SMS
and PWT air interface
synchronization signals
8 calls
8 Base Stations
60 simultaneous calls
46 simultaneous calls
60 individual extensions
48 individual extensions
8 PBX lines (analog, 2 wires)
12 PBX lines (1:1 digital lines)
8 Base Stations – 2.2 miles
8 Base Stations – 1.2 miles
8 calls
3+7 CLU or 3+7 SLU power ports
for Base Station power
PC, Printer/SMS and General
Alarm
1 input and 3 output PWT air
interface synchronization
connections
Technical Product Manual - DCT1900
Configuration Directions, Relation between Parts
Remarks
Number of System Boards may be less due to
power limitations. Up to 4 cabinets can be chained.
An MCCB is factory mounted.
Only 1 per system (also with a multi–cabinet
system).
CPU/SDB synchronization cables.
Note: Sync Kit required for each CPU. FPGA
must be installed.
An SLU consists of an SPU part and a CLU part.
The SLU can be combined with SPU and CLU
boards.
The SPU part provides for 8 speech paths. The CLU
part can connect 8 Base Stations.
CLU/MDF Cables and CLU/MCCB Power cables.
Quantity depends on required traffic capacity and
GOS.
Two 2–Mbit links, each link having 30 channels to
which Portable Telephones are assigned
dynamically. The maximum number of Portable
Telephones depends on the GOS and the traffic
capacity of the RE configuration (1 per RE)
Two 1.544-Mbits, each link having 23 channels to
which Portable Telephones are assigned
dynamically. The maximum number of Portable
Telephones depends on the GOS and the traffic
capacity of the RE configuration (1 or 2 per RE).
Two 2–Mbit links, each link having 30 channels to
which Portable Telephones are assigned on a
dedicated basis. (Max. 10 per system)
Two 1.544-Mbits, each link having 24 channels to
which Portable Telephones are assigned on a
dedicated basis. (Max. 13 per system)
LTU/MDF Cable Set- 1 cable supports 3 LTUs . A
maximum of 272 Portable Telephones supported.
DLU/PBX Cable Set- 1 cable supports 2 DLUs. Each
DLU supports 12 Portable Telephones.
CLU/MDF Cables and CLU/MCCB power cables.
The SPU provides 8 speech paths. Quantity
depends on required traffice and GOS.
Modular Cabinet Connection Board
To be mounted on the bottom plate of the Modular
Cabinet.
6-1