Outline Drawings - TDK-Lambda Genesys GEN8-300 User Manual

Programmable dc power supplies 2.4kw in 1u built in rs-232 & rs-485 interface advanced parallel operation
Hide thumbs Also See for Genesys GEN8-300:
Table of Contents

Advertisement

2.13 GENESYS
Note 4
A
57.8+/-0.5
92.0+/-0.5
NOTES:
1.Mating plug supplied with power supply.
2.Bus-bars for 8V to 100V models. See detail.
Wire clamp connector for 150V to 600V models (shown).
3. AC cable strain relief (supplied with power supply).
4. Chassis slides: GENERAL DEVICES P/N: CC3001-00-S160
or equivalent, mounting holes #10-32 marked "A".
5. Bus Bars enclosure for 60V to 600V.
TM
2400W POWER SUPPLIES

OUTLINE DRAWINGS

T D L amb da
- I
482.8+/-1.0mm
422.8+/-1.0mm
Note 1
Note 2 (150V~600V)
603.0+/-1.0mm
A
A
92.0+/-0.5
440.8+/-1.0mm
GEN8-300
0-8V
0-300A
Note 1
13
13
Note 3
Note 2
Bus-Bar Detail
8V to 100V Models
3.0mm
22.0mm
8.5mm
30.0mm
Note 5

Advertisement

Table of Contents
loading

Table of Contents