Diagnostic Tests

The following diagnostic tests are available in the test menu. Time is specified for
each action in the test, and the total time equals the time it takes to complete each
action. If the time is zero the luminaire will perform the test at full speed.
For specific DMX values for each test see
Test Descriptions (In alphabetical order)
ALL1 .......................... Tests low voltage power supplies by moving all motors at once.
ALL2 .......................... Tests all functions and provides a burn in or soak test.
Bl 1/Amb1/MAG1 ...... Fast color mixer tests, Goes from full color to open.
Bl 2/Amb2/MAG2 ...... Slow color mixer tests, Goes from full color to open.
Bl 3/Amb2/MAG3 ...... Tests different color mixer positions.
Cw 1 .......................... Steps through each position of color wheel to verify order. The
Cw 2 .......................... Tests color wheel stabilizers. Performs Max reverse spin, stops
Cw 3 .......................... Test color wheel stabilizers. Steps through selected colors.
DiF1........................... Fast diffusion test from stop to stop.
DiF2........................... Slow diffusion test from stop to stop.
DiF3........................... Tests different diffusion positions.
Dim1 .......................... Fast dimmer test from full to closed.
Dim2 .......................... Slow dimmer test from full to closed.
Dim3 .......................... Tests different dimmer moves.
MiX1 .......................... Fast color mixer test where all colors are operating.
MiX2 .......................... Slow color mixer test where all colors are operating.
MiX3 .......................... Tests different positions with all colors operating. Verifies the
PT1............................ Fast pan and tilt from stop to stop.
PT2............................ Slow pan and tilt from stop to stop.
P 1 ............................. Fast pan only test from stop to stop.
P 2 ............................. Slow pan only test from stop to stop.
P 3 ............................. Tests different pan movements.
T 1 ............................. Fast tilt only test from stop to stop.
T 2 ............................. Slow tilt only test from stop to stop.
T 3 ............................. Tests different tilt movements.
Strb............................ Strobe test that tests 0-Open, 4-Closed, 11-Fast Random, 255-
The chart on the following page shows the 16-bit DMX values used in each test.
72
L
U
'
ASH
UMINAIRE
SER
S
test then performs a Max forward spin, stops, and performs a
Max reverse spin.
on a color, and then stops on the sensor.
color match for VL2416.
Max Strobe actions.
17-Sept-01
M
ANUAL
"Diagnostic Tests" on page
73.